background image

6

1292000-W2-B

Applicator

Clamp Bracket

Slide Bar

Constant Friction 

Mechanism and 

Friction Pad

25 mm Minimum

Spill-over level

Hose Retaining Ring

Note!

 For dry lined, stud partition, shower cubicle or laminated panel walls the installer may 

wish to obtain alternative proprietary cavity fixings. Use of these alternative fixings is beyond 

the scope of this guide.

Important!

  If  the  Logic  slide  bar  replaces  an  existing  Mira  slide  bar  make  sure  that  the 

position of the shower control and the shower fittings provide a minimum of 25 mm between 

the handset and bath/tray spill-over level. This is necessary to prevent back-siphonage. If 

this is not possible then the new slide bar will have to be repositioned.

Mira Logic Exposed Variable Shower Fittings (ev)

Read the section: 

Installation Requirements 

before proceeding with the installation.

The slide bar should be positioned to one side of the shower control at a convenient height 

for all the family. It should be positioned so that the handset discharges down the centre line 

of the bath, or across the opening of the shower cubicle. The handset should be directed 

away from the shower control.

1.

  Decide on a suitable position for the slide 

bar  avoiding  buried  cables  and  pipes. 

Make sure that when the hose retaining 

ring is placed on the lowest position on 

the slide bar there is a minimum of 25 mm 

between the handset and bath/tray spill-

over level. This is necessary to prevent 

back-siphonage.

2.   Important! 

The  slide  bar  has  been 

supplied with an applicator fitted to one 

end  (refer  to  illustration)  to  assist  the 

assembly  of  the  slide  bar  through  the 

clamp bracket.

 

With  the  clamp  bracket  button 

FULLY

 

depressed  carefully  ease  the  slide  bar 

through the hole in the clamp bracket.Take 

care not to dislodge the constant friction 

mechanism or the friction pad.

3.

  Release  the  clamp  bracket  button. 

Remove the applicator from the slide bar 

and store in a safe place for future use.

4.

  Slide the hose retaining ring onto the slide 

bar below the clamp bracket.

Installation

8.

  The minimum pressure required for a satisfactory spray pattern to form, at the handset or 

spray head, is 0.1 bar. For a gravity fed shower installation the minimum head of water 

required, to accommodate the pressure loss in the pipes and shower control of a typical 

installation, is 1.0 metre.

  

For a pump installation the minimum acceptable vertical distance between the base of 

the cold water storage cistern and the shower head to operate the pump’s flow switches, 

is typically 0.6 m (600 mm).

Содержание Mira Logic

Страница 1: ...ructions must be left with the user Mira Logic Shower Fittings Adjustable Range If you experience any difficulty with the installation or operation of your new shower fittings then please refer to Fault Diagnosis before contacting Kohler Mira Limited ...

Страница 2: ...afe manner in accordance with current local authority recycling or waste disposal policy Important Safety Information This Installation and User Guide covers the following products Mira Logic Exposed Variable Shower Fittings ev An adjustable spray handset with four different spray actions supplied complete with flexible hose clamp bracket assembly slide bar supports and hose retaining ring gel hol...

Страница 3: ...ssembly 1 x Hose Retaining Ring 2 x Fixing Screws 2 x Wall Plugs 1 x 1 25m Flexible Hose 1 x Slide Bar 2 x Hose Seals 1 x Applicator Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included Mira Logic ev and biv Shower Fittings Pack Contents ...

Страница 4: ...Seal 1 x Backplate 2 x Wall Plugs 2 x Backplate Screws 1 x Olive 1 x Olive Nut Mira Logic biv Shower Right Angle Connector Fittings Pack Mira Logic ev and biv Shower Fittings 344 mm Max 659 mm Dimensions 1 x Hexagonal Wrench 1 x Screw ...

Страница 5: ... dropping below the spill over level of the bath or shower tray This will prevent water supply contamination due to backsiphonage 2 Installations must comply with UK Water Regulations Bye laws Scotland and Building and Plumbing Regulations in force at the time of installation 3 When installing the shower fittings in a cubicle position with the spray pointing across rather than toward the opening o...

Страница 6: ...on a suitable position for the slide bar avoiding buried cables and pipes Make sure that when the hose retaining ring is placed on the lowest position on the slide bar there is a minimum of 25 mm between the handset and bath tray spill over level This is necessary to prevent back siphonage 2 Important The slide bar has been supplied with an applicator fitted to one end refer to illustration to ass...

Страница 7: ...ated panel walls 8 Fix the bottom slide bar support to the wall using the screw provided Make sure that the screw is fully tightened 9 Loosely screw the top slide bar support to the wall Press firmly down on the top slide bar support and while continuing to apply force fully tighten the screw 10 Fit the end caps to the slide bar supports 11 Check the slide bar cannot be rotated or vertically moved...

Страница 8: ...r control Make sure that the hose washer is fitted 2 Pass the flexible hose through the hose retaining ring and screw the remaining end of the hose onto the handset Make sure that the hose washer is fitted 3 Place the handset in the clamp bracket assembly Handset Hose Washer Clamp Bracket Assembly Hose Retaining Ring ...

Страница 9: ...m the pipework back to the required depth from the finished wall surface Remove all burrs and sharp edges Installation of the Right Angle Connector 3 Drill the fixing holes 7 mm diameter for screws supplied DO NOT drill through the backplate into the wall DO NOT drill into buried cables or pipes 29 33 mm 90 1 2 ...

Страница 10: ...work to clear all debris Install the O ring over the pipe Fit the cover and twist to lock Secure the backplate to the wall so the foam seal is fully compressed 5 Fit the pipe collar and lock Re check the pipe length 29 33 mm foam seal ...

Страница 11: ...11 1292000 W2 B Check for leaks 8 9 Tighten the screw using the 3 mm hex key supplied to lock the assembly Fit a shower hose with a 15 mm rubber washer 10 ...

Страница 12: ...Mode 4 First second and third row ON Clamp Bracket Adjustment ev and biv shower fittings only 1 Depress the release button and slide the clamp bracket assembly to the required position 2 Move the handset to the required angle Afriction mechanism within the clamp bracket assembly will hold the handset at the desired angle Release Button Clamp Bracket Assembly ...

Страница 13: ...n over a few minutes Problem with shower control This is quite normal Changing the angle of the shower fitting may vary the draining time Refer to the shower control Installation and User Guide Shower temperature changes when spray action is adjusted Adjusting the spray action changes the flow of water This may affect some shower controls and plumbing installations To minimise the effect make sure...

Страница 14: ...BSM 450 30 Hose Retaining Ring Chrome 1867 045 Adjustable Handset Assembly Chrome 450 17 Slide Bar Wall Fixing Pack Components Identified A 1844 166 RAC Connector Mounting Pack 450 24 Clamp Bracket Assembly Chrome 450 27 Slide Bar Support Assembly Components Identified B A A B B 450 28 Slide Bar Chrome 1844 165 RAC Connector Shroud Chrome ...

Страница 15: ...15 1292000 W2 B Notes ...

Страница 16: ...n for loss of use of the product or consequential or indirect loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replacement parts to repaired or modified by persons not authorised by comply with the requirements of the TMV2 or repaired or modified by persons not authorised by TMV3 ...

Отзывы: