6
SPECIFICATIONS
Pressures
Maximum Static Pressure:
10 Bar
.
Minimum Maintained Pressure (Gas Water Heater):
1.0 Bar
.
(for optimum performance initial supplies should be nominally equal).
Minimum Maintained Pressure (Gravity System):
0.1 Bar
.
(0.1 bar = 1 Metre head from base of cold tank to the outlet of the shower handset).
Maximum Maintained Pressure:
5 Bar
.
Temperatures
Factory Pre-set (Blend) Shower:
43°C
.
Optimum Thermostatic Control Range:
35°C - 45°C
.
(Achieved with supplies of 15°C cold, 65°C hot and nominally equal pressures).
Max. Hot Supply:
85°C
.
Recommended Hot Supply:
60°C - 65°C
.
Min. Differential between Hot Supply and Outlet Temperature:
10°C
.
Cold Water Range:
1°C - 20°C
.
Flow Rates
Typical Flow Rates - Mira Discovery Dual Control with Adjustable Fittings:
Start (Outer Spray)
Soothe (Middle Spray)
Force (Inner Spray)
Rigid (Fixed Spray)
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
2
4
6
8
10
12
14
16
18
Supply Pressure (Bar)
Flow Rate (L/Min)
With 12 L/Min Flow
Regulator Fitted