Operation and Maintenance Manual
Operating fluids and maintenance
Maintenance activities
Fig. 65
While another person operates the turning device,
u
Remove the V-ribbed belt (crankcase ventilation)
5
.
Perform maintenance work “change oil separator filter insert of the crankcase
breather”.
While another person operates the turning device,
u
fit the new V-ribbed belt, making sure that it is properly seated.
Procedure for mounting the fan drive assembly
4
:
u
Mount fan drive assembly
4
.
u
Tighten external hexalobular screws
3
(M18 10.9 E24).
Tightening instructions for external hexalobular screws (M18 10.9 E24)
Step
Torque
1.
125 Nm
92 ft lb
2.
250 Nm
184 ft lb
Tab. 33: Tightening instructions
KD27V12 33521029401_3_1 en 2017-07-01
© 2017 by Kohler Co. All rights reserved.
83
Содержание KD27V12
Страница 111: ......
Страница 112: ...33521029401_3_1 EN 07 2017 LHID11433940 2016 by Kohler Co All rights reserved...