Operation and Maintenance Manual
Operating fluids and maintenance
Maintenance activities
q
Turning device ID no. 10123791 is available.
WARNING
Rotating parts!
Risk of injury! Causes serious injuries.
u
Turn the Diesel engine off.
u
Secure the engine against unexpected starting.
Fig. 56: V-ribbed belt drive
u
Remove fan from the fan drive
1
. See the generator set’s operating manual.
u
Remove the V-ribbed belt (fan)
2
. (For the procedure, please refer to the
chapter “Check state of fan drive belt drive, replace if necessary”.)
u
Dismantle the bracket
3
. (Please refer to the chapter on “Changing the
crankcase breather belt” for the procedure.)
KD27V12 33521029401_3_1 en 2017-07-01