Operation and Maintenance Manual
Operating fluids and maintenance
Maintenance activities
Fig. 58: Filter insert
u
Release socket head screws
10
(M8 10.9).
u
Remove filter insert
9
.
u
Dispose of filter insert
9
(observe country-specific regulations).
u
Fit the new filter insert
9
and sealing rings.
u
Tighten socket head screws
10
(M8 10.9).
u
Install the crankcase ventilation
8
.
u
Tighten hex screws
7
(M8 8.8).
u
Fasten line
6
.
u
Tighten hose clips
5
.
While another person operates the turning device,
u
lay on new V-ribbed belt (crankcase breather)
4
and ensure it is correctly
seated.
u
Install the bracket
3
. (Please refer to the chapter on “Changing the crankcase
breather belt” for the procedure.)
u
Mount belt (fan)
2
. (For the procedure, please refer to the chapter “Check state
of fan drive belt drive, replace if necessary”.)
u
Mount fan on the fan drive
1
. See the generator set’s operating manual.
KD27V12 33521029401_3_1 en 2017-07-01
© 2017 by Kohler Co. All rights reserved.