E. How To Remove The Pillow Bracket
¨
Loosen the inner hexagon screw on the bottom of the pillow bracket, and then remove the pillow form the
bath.
G. Make Electrical Connections
F. How To Remove The Grip Rail (Optional)
¨
Loosen the inner hexagon screw on the bottom of the grip rail, and then remove the grip rail form the bath.
Installation (Cont.)
Inner Hexagon Screw
Inner Hexagon Screw
WARNING: Risk of electric shock.
To reduce the risk of electrical shock, connect the control box to
a properly grounded, grounding-type receptacle protected by Ground-Fault Circuit-Interrupters (GFCI ‘s).
Do not remove the plug grounding pins. Do not use grounding adapters.
NOTE:
Electronic parameter label located on the controller. This label also identifies the electrical rating.
¨
Your Kohler bath with airjets is equipped with a cord and plug. The blower motor has been wired at the
factory. A licensed electrician must install a dedicated GFCI-protected, 220 V, 10 A, grounded outlet.
¨
Plug the control box into this outlet.
¨
Clean the area of all dust and debris.
H. Test Run the Bath with Airjets
¨
Check all electrical connections, and make sure the electrical power to the bath with airjets is on.
¨
Make sure all piping connections in the air harness are secure.
¨
Verify that the blower motor is secure.
¨
Temporarily remove the plastic drop cloth or other protective sheeting from the bath.