3. Cut the Pipes
Measure the distance between the two marks on the inlet pipe to
determine
″
A.
″
Measure and mark
″
A
″
from the end of the side opposite the
gasket on the inlet pipe.
Cut the inlet pipe at this location.
Measure the distance between the two marks on the outlet pipe
to determine
″
B.
″
Measure and mark
″
B
″
from the end of the side opposite the
gasket on the outlet pipe.
NOTE:
Confirm the finished wall line is closer to the outlet end of
each pipe.
Cut the outlet pipe at this location.
Use a file to remove all rough areas on the cut end of each pipe.
Reinstall the pipes on the bowl.