OPERATING YOUR BATH WITH AIRJETS(CONT)
7
-T01-B
1200098
STOPPING THE BATH
!
!
!
!
After taking the bath, touch the pump on/off button
"
" a second time to stop the air system.
Carefully exit the bath.
Touch the electronic drain on/off button"
". The
green light flashes.
When water in the bath is almost emptied, the
automatic two-minute purge cycle occurs. The air
system operates at a low speed to blow any residual
water out of the air channels.
!
!
!
!
/
/
2
INITIATING A MANUAL PURGE CYCLE
!
!
!
After the bath is drained, touch the manual purge
button "
" once.
The purge icon flashes green and the mode is
implemented. The air system operates at a low
speed to blow any residual water out of the air
channels.
After about two minutes, the air pump stops
automatically.
!
!
!
NOTE:
When the bath reaches overflow level,
water level may rise quickly if you enter the bath
or start the bubble massage function, which may
trigger the compelling drain function. Compelling
drain function will discharge lots of water, so it is
not recommended to use the bath when it
reaches overflow level.
COMPELLING DRAIN FUNCTION
!
If the overflow level sensor does not work, you can
use the compelling drain function to prevent water
overflow to your bathroom. Please refer to the
automatic drain water level in the Roughing-in.
!
POWER OFF STATUS
!
The electronic drain automatically starts under
power off status.
Please do not use the bath in case of outage. In
this case, the electronic drain automatically opens and
the bath can not be filled with water.