background image

113864-5-BB

3

1041246-T01-C

-T01-B

1200098

(GFCI)

(ELCB)

GFCI

ELCB

GFCI

ELCB

GFCI

ELCB

GFCI

ELCB

GFCI

ELCB

GFCI

ELCB

Never drop or insert any object into any opening.

The bath with airjets must be connected only to a
supply circuit that is protected by a Ground-Fault
Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-
Breaker (ELCB). Such a GFCI or ELCB should be
provided by the installer and should be tested on a
routine basis. To test the GFCI or ELCB, press the test
button. The GFCI or ELCB should interrupt power.

Press the reset button. Power should be restored. If

the GFCI or ELCB fails to operate in this manner, the
GFCI or ELCB is defective. If the GFCI or ELCB
interrupts power to the bath without the test button
being pressed, a ground current is flowing, indicating
the possibility of an electric shock. Do not use this bath.
Disconnect the bath and have the problem corrected by
a qualified service representative before using.

IMPORTANT INFORMATION

INSTRUCTIONS PERTAINING TO A RISK OF FIRE,

ELECTRICAL SHOCK, OR INJURY TO PERSONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING: When using electrical products,
basic precautions should always be followed,
including the following:

DANGER: Risk of personal injury.

WARNING: Risk of personal injury.

WARNING: The use of alcohol, drugs, or
medication can greatly increase the risk of
fatal hyperthermia.

To reduce

the risk of injury, do not permit children to use
this unit unless they are closely supervised at all
times.

To avoid

injury, exercise care when entering or exiting the
bath with airjets.

Prolonged immersion in hot

water may induce hyperthermia.

NOTE:

Please do not use the bath in case of

outage. In this case, the electronic drain
automatically opens and the bath can not be
filled with water.

Use this bath with airjets only for its intended purpose
as described in this manual. Do not use attachments
not recommended by the manufacturer.

Содержание K-45720T

Страница 1: ...1 368 201419 Bubble Massage Bath Include Electronic Drain and Soft Touch Panel OWNER S MANUAL 2014 Copyright Kohler China Ltd 2014 1200098 T01 B...

Страница 2: ...expectations We re proud of our bath with airjets here at Kohler and we know you will be too Please take a few minutes to study this Homeowners Guide before you use your bath with airjets Pay special...

Страница 3: ...have the problem corrected by a qualified service representative before using IMPORTANT INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL...

Страница 4: ...oft Touch Panel Airjets Blower Motor Electronic drain YOUR KOHLER BATH WITH AIRJETS 4 T01 B 1200098 FUNCTION OPERATION 38 c o Manual Purge Electronic Drain On Off Pump On Off Water Temperature Decreas...

Страница 5: ...the massage function is off the blower motor will automatically start and stop after running for about 2 minutes if it detects the water level is below the airjets 2 2 Temperature Display Display wate...

Страница 6: ...f necessary slide the sliding panel to adjust the airflow NOTE Before operating the panel please confirm that there is no obvious water stains on the panel If there is any please first wipe it clean 2...

Страница 7: ...ter out of the air channels After about two minutes the air pump stops automatically NOTE When the bath reaches overflow level water level may rise quickly if you enter the bath or start the bubble ma...

Страница 8: ...roducts in aerosol cans To restore dull or scratched units Apply white automotive polishing compound with a clean rag Rub scratches and dull areas vigorously Wipe off residue Follow with a coat of whi...

Страница 9: ...B A B C A B C C D D This troubleshooting guide is for general aid only A Kohler Authorized Service Representative or qualified electrician should correct all electrical problems For warranty service...

Страница 10: ...ol A Replace controller A Check wire connections If necessary replace user keypad B Replace user keypad C Replace the controller A Replace blower motor B Check wire connections If necessary replace wa...

Страница 11: ...eypad 8 Manual purge cycle does not work 10 Cannot operate or stop electronic drain 9 Massage pillow does not work A User keypad cable loose or damaged A User keypad trips A Malfunction of mechanism B...