6. Installation Checkout
Plug the media module power supply into the outlet. Verify that the indicator light on the media
module turns on and pulses.
Turn on the water supply to the valve (if equipped).
Check all connections for leaks and make any adjustments as needed.
Turn on the main power supply. You should hear the valve power up and the power icon on the
user interface will be lit with a green pulsing light.
If not already completed, refer to the
″
Digital Interface User Guide
″
to set up the interface.
NOTE:
For more information about using the user interface and its menus, refer to the user interface
Homeowners Guide.
For installations with a digital mixing valve:
Press the [Power Icon] and then press the [OK Icon]
to turn on the bath filler. Turn on the handshower by pressing the [Options Icon], then using the
interface dial, scroll to
″
Handshower
″
and select by pressing the [OK Icon]. This will turn on all the
valve outlets and purge the air from the system.
Check for leaks and make any adjustments as needed.
Verify that the water flow is sufficient for your bathing needs.
Troubleshooting
CAUTION: Risk of personal injury.
The valve (if installed) may contain hot water; be careful when
draining any residual water.
IMPORTANT!
Turn off the power and water supply to all components before performing any
maintenance.
It is recommended that any valve maintenance should be performed by a Kohler Co. Authorized Service
Representative.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4-KOHLER.
Interface Troubleshooting Table
Symptoms
Probable Cause
Recommended Action
1.
Digital interface is not lit.
A.
Media module is not plugged
into the outlet.
A.
Plug the media module into the
outlet.
B.
Power supply connection to the
media module may be loose or
disconnected.
B.
Check power supply connections to
the media module and reconnect if
needed.
C.
Interface cable connections may
be loose or disconnected.
C.
Check all interface cable
connections, connect if needed.
D.
Circuit breaker has been
tripped.
D.
Reset the circuit breaker.
E.
The media module may require
resetting.
E.
Disconnect and reconnect the
power supply from the media
module.
F.
If none of the recommended
actions for the above issues
correct the symptom, the media
module or interface requires
servicing.
F.
Contact your Kohler Co.
Authorized Service Representative.
2.
The interface power
indicator pulses but does
not turn on.
A.
Interface cable connections may
be loose or disconnected.
A.
Check all interface cable
connections, connect if needed.
B.
The media module requires
resetting.
B.
Disconnect and reconnect the
media module power supply.
1093343-2-B