background image

Product Information

Applicable product:
Bath whirlpool with integral

apron, left drain

K-1122-LA

shown

Bath whirlpool with integral

apron, right drain

K-1122-RA

not shown

Fixture*:
Bathing well
Basin area bottom

45-1/8

(114.6 cm) x 19-11/16

(50 cm)

Basin area top

52-3/4

(134 cm) x 25-5/16

(64.3 cm)

Weight

135 lbs (61.2 kg)

To overflow
Water depth

15

(38.1 cm)

Capacity

58 gal (219.5 L)

* Approximate measurements for comparison only.

Pump:

Hp

V

Hz

A

1-speed

1.25

120

60

7

Pump is supplied with 24

(61 cm) grounding-type plug-in

cord.

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Locate the outlet behind the whirlpool and within 24

(61 cm)

of the pump.

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

49 lbs/square foot (240 kg/square meter) loading.
The hot water supply should be 70% of the capacity of the bath or

greater. Installations will vary.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

No change in measurements if connected 
with drain illustrated. (K-7272)

1/2" (1.3 cm) R.

1-1/2" OD

60" (152.4 cm)

Integral Flange 
Detail

1-1/4" 
(3.2 cm)

16"
(40.6 cm)

2-1/2"
(6.4 cm)

3/4"
(1.9 cm)

11-1/4"
(28.6 cm)

19"
(48.3 cm)

1-1/4"
(3.2 cm)

32" (81.3 cm)

1063752-1-B

2

Kohler Co.

Содержание K-1122-LA

Страница 1: ...numbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1122 LA K 1122 RA 1063752 1 B 2007 Kohler Co ...

Страница 2: ...ired protected with a Class A Ground Fault Circuit Interrupter GFCI Pump control 120 V 15 A 60 Hz Locate the outlet behind the whirlpool and within 24 61 cm of the pump Notes Install this product according to the installation guide Floor support under this product must provide for a minimum of 49 lbs square foot 240 kg square meter loading The hot water supply should be 70 of the capacity of the b...

Страница 3: ...4 61 cm Branchement électrique requis Circuit dédié requis protégé par un Disjoncteur Différentiel de Classe A GFCI Pompe contrôle 120 V 15 A 60 Hz Localiser la prise de courant derrière la baignoire à hydromassage à moins de 24 61 cm de la pompe Remarques Installer ce produit selon le guide d installation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 49 lbs pied c...

Страница 4: ...os eléctricos Requiere un circuito dedicado protegido con un interruptor de circuito con pérdida a tierra GFCI de Clase A Bomba control 120 V 15 A 60 Hz Coloque el tomacorriente detrás de la bañera de hidromasaje y a menos de 24 61 cm de la bomba Notas Instale este producto conforme a la guía de instalación El soporte del piso debajo de este producto debe poder soportar una carga mínima de 49 lbs ...