22. Troubleshooting Procedures
For All Installations
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Troubleshooting the Bath with Airjets System
Symptoms
Probable Causes
Recommended Action
1.
User keypad does not
illuminate when power
button is pressed or the
outer ring is rotated.
A.
No power to control.
A.
Check wiring and connect power.
B.
Ground-Fault Circuit-Interrupter
(GFCI) or Earth Leakage Circuit
Breaker (ELCB) tripped.
B.
Reset GFCI or ELCB. If it trips
again, refer to
″
Ground-Fault
Circuit-Interrupter (GFCI) or Earth
Leakage Circuit Breaker (ELCB)
trips when bath with airjets is
turned on
″
.
C.
Wiring harness from user
keypad to control is loose,
disconnected or damaged.
C.
Check wiring for proper
connections. Replace the wiring
harness if necessary.
D.
User keypad does not work.
D.
Replace the user keypad.
E.
Control does not work.
E.
Replace the control.
2.
Ground-Fault
Circuit-Interrupter (GFCI)
or Earth Leakage Circuit
Breaker (ELCB) trips
when bath with airjets is
turned on.
A.
Electrical harness is wet or
damaged.
A.
Check for wet connections. Dry the
connections and repair the leak.
Check for insulation or connector
damage. Replace the harness if
damaged.
B.
Electrical wiring to the bath
junction box is wet or damaged.
B.
Have a qualified electrician
diagnose and correct the problem
in accordance with applicable
building and electrical codes.
C.
Electrical wiring to the bath
power cord is wet or damaged.
C.
Have a qualified electrician
diagnose and correct the problem
in accordance with applicable
building and electrical codes.
D.
Blower motor is shorted
internally.
D.
Replace the blower motor.
E.
Control is shorted internally.
E.
Replace the control.
Air Flow Mode
Activates Mode Selected
Power On/Off
Indicator Bar
Decrease Flow or Surge
Increase Flow or Surge
Rotating Ring Key Pad
Zone 1
Zone 2
Zone 3
Surge Mode
Purge Mode
Chromatherapy Specific
Color (if provided)
Chromatherapy Cycle
(if provided)
Rotate Outer Ring to
Access Desired Mode
Kohler Co.
29
1035472-2-F