Troubleshooting Procedures (cont.)
Symptoms
Probable Causes
Recommended Action
B.
Loose, disconnected, or
damaged wiring harness.
B.
Check wiring for proper
connections. Replace the wiring
harness if necessary.
C.
User keypad does not work.
C.
Replace the user keypad.
D.
Blower motor does not work.
D.
Replace the blower motor.
E.
Control does not work.
E.
Replace the control.
9.
Blower motor won’t turn
off when the power
button on user keypad is
pressed.
A.
User keypad does not work.
A.
Replace the user keypad.
B.
Loose, disconnected, or
damaged wiring harness.
B.
Check wiring for proper
connections. Replace the wiring
harness if necessary.
C.
Control does not work.
C.
Replace the control.
10.
A zone does not produce
air bubbles but another
zone operates normally.
A.
Zone is not selected.
A.
Select the zone as per the
instructions in the
″
Confirm Proper
Operation
″
section.
B.
Butterfly valve does not work.
B.
Replace the butterfly valve.
C.
Loose, disconnected, or
damaged wiring harness.
C.
Check wiring for proper
connections. Replace the wiring
harness if necessary.
D.
User keypad does not work.
D.
Replace the user keypad.
E.
Control does not work.
E.
Replace the control.
11.
Surge mode does not
work.
A.
User keypad does not work.
A.
Replace the user keypad.
B.
Control does not work.
B.
Replace the control.
12.
Water spillage or damage
observed under the bath.
A.
Drain or overflow leaking.
A.
Repair or replace the drain
assembly as per the manufacturer’s
instructions.
B.
Wall, deck, and/or shower door
is improperly sealed.
B.
Apply silicone sealant at the seams
between the bath and the wall,
deck, or door.
C.
Cracked acrylic air channels.
C.
Refer to the manufacturer.
13.
Bath does not purge
automatically.
A.
Level sensor wires are
disconnected.
A.
Connect the level sensor wires.
For Baths with Chromatherapy
Symptoms
Probable Causes
Recommended Action
14.
Chromatherapy lights do
not work.
A.
Loose, disconnected or damaged
wiring/connections.
A.
Check wiring for proper
connections. Replace wiring if
necessary.
B.
Control does not work.
B.
Replace control.
15.
Chromatherapy does not
cycle.
A.
Chromatherapy harness
assemble does not work.
A.
Replace the chromatherapy harness
assembly.
Kohler Co.
31
1035472-2-F