1. Install the Control Stop
IMPORTANT!
Flush the water supply line and then turn off the
water supply.
For K-10675 and K-10676 Only
Cut the water supply tube and sweat-solder the 3/4
″
male NPT
threaded adapter to it.
NOTE:
Install the adapter so that the centerline of the externally
threaded control stop arm matches the centerline of the spud when
assembled.
Place the wall flange over the water supply tube and slide it
against the finished wall.
Place the sleeve over the water supply tube. If required, cut the
sleeve to size.
NOTE:
Use thread sealing compounds only on male NPT threads.
Apply thread sealant to the male NPT threaded adapter.
Thread the control stop valve onto the threaded adapter.
Thread the stop cap onto the control stop using a strap wrench.
Use a strap wrench in order to tighten the control stop and align
the outlet to the valve inlet.
Wall Flange
Sleeve
Control Stop
Stop Cap
1108712-2-A
6
Kohler Co.