-17-
B.
(1)
(2)
Floating Box
Drainage valve
Adjustment Switch
B. Adjust Drainage Valve
Drainage volume and overflow level of the tank can be
adjusted by drainage valve:1) heavy drainage adjustment:
open adjustment switch to open the small hole. 2) slight
drainage adjustment: adjust the height of floating box and
the water level of slight drainage will be at the bottom of
the floating box.
C.
C. Adjust Inlet Valve
Hoist and reduce the water level in the tank by adjusting
the control pole. Turn the control pole counterclockwise to
lower down the floating box and reduce the water level of
the tank .turn the control pole clockwise to hoist the
floating box and increase the water level in the tank.
Control Pole
Inlet Valve
Floating Box
TROUBLE SHOOTING PROCEDURES
TROUBLE SHOOTING PROCEDURES
No water fills in via inlet
valve
The inlet valve is closed.
Open inlet valve.
Floating box of inlet valve is blocked by other parts.
Floating box of inlet valve is block by waste.
Wash the floating box with clean water.
No drainage when
pressing the heavy and
slight drainage button
Too high or too low water
level
Leak of the toilet and
squat
Toilet does not flush
Toilet does not flush
completely
Symptoms
Probable Causes
Recommended Action
The pole and the reversed lock are not connected.
Reinstall the reversed lock onto the pole of
the outlet valve.
The floating box of the inlet valve is not properly
adjusted.
Readjust the water level.
The floating box of the inlet valve is blocked by
wastes, so the water is leaked from the overflow
pipe.
A. No water supply.
B. The water supply stop is closed.
Readjust the position of other parts to avoid
contacting the floating box when it is
functioning.
A. Wait for restoration of water supply.
B. Open the water supply stop.
Readjust the position of other parts to avoid
contacting the floating box when it is
functioning.
The rubber gasket is blocked by wastes.
Filter screen is clogged.
Take out the outlet valve and clean the
wastes.
Refer to wash filtration net.
The adjustable board and the long screw are
wrongly installed.
Reinstall the long screw.
1263048-T01-C