background image

-12-

2. Make sure of h according to dimensions of bowl and then

locate the installation hole of fixing bracket. Mark on the
wall for appropriate position for fixing bracket, and drill four
holes with diameter of 10mm and depth of 80mm with
churn drilling as shown in illustration, and fill in the holes
with bulge screw and tighten the screw to set the fixing
bracket.

Note: Ensure the fixing bracket to remain level.

2.

h

10mm

80mm

O

Fixing Bracket

Bulge Screw

Gasket

Spring

Nut

h

3. Put the tank onto the fixing bracket as shown in the right

figure and adjust the tank to level . Then tighten screws
with hex-head key. Note: it is a must to keep the tank level.

Connect the inlet hose with tank inlet pipe.

Note: 1. Ensure water tank internal valve is OFF.

2. Suggestion: connect a temporary rubber or plastic

hose on valve, flush water supply pipeline. Ensure
water is clean, no residual sand stone or fouling
inside pipeline.

3.

1.
2.

Water Pipe

Screw

Level

Tank

Tighten

Loosen

Medium
Allen Key

Connecting Pipe

Mask

Screw

Water Tank

Protective Cover

4. Install the mask in the block screen of the tank, and

tighten the screw to fix the mask to the tank.

4.

5. Insert the inlet pipe and drainage pipe into the bowl, and

then adjust the syphon and drainage pipe to a proper
position to be fixed into the bowl. Make sure of the
positions of syphon and discharge elbow and then remove
the bowl.

5.

Inlet Pipe

Syphon

Discharge Elbow

Drainage Pipe

1263048-T01-C

Содержание HYDRO-TOWER 300

Страница 1: ...nstall the tank according to instructions in the guide to avoid product damage and installation inconvenience caused by inappropriate operation All data contained is based upon the last product inform...

Страница 2: ...application of in wall tank pipes and connectors The most remarkable advantage of in wall tank is that the installation will never be limited to certain area and can be installed wherever as you wish...

Страница 3: ...e measure Seal tape Bushing Lubricant 3 ROUGHING IN UNIT mm Reference Value K 4179T K 4178T 478 3 88 2 438 3 681 4 269 5 35 2 100 3 205 3 1048 4 1066 4 1098 4 Finished floor 90 142 18 62 45 95 90 0 5...

Страница 4: ...Installation Method Three discharge pipe installation methods based on actual situation A B C adjust position by screw driver Snap discharge pipe lower end into discharge port A B C B C A Discharge El...

Страница 5: ...board inside water tank first as shown Then remove board and plug above bracket assembly 1 Plug Paper Board Board 2 Loose hex head screw and adjust mounting bracket height as shown in Fig A Loose hex...

Страница 6: ...Bulge Screw Bulge Screw Gasket Gasket Nut Nut 4 Tighten the nut with the wrench as shown in illustration A Tighten the nut with the wrench as shown in illustration B 4 A B A B Nut Nut Wrench Wrench B...

Страница 7: ...is OFF 2 Suggestion connect a temporary rubber or plastic hose on valve flush water supply pipeline Ensure water is clean no residual sand stone or fouling inside pipeline 3 1 2 Water Pipe Connecting...

Страница 8: ...mask with a sharp knife Big Cap Small Cap D Installation of Toilet D 1 Install the inlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pencil and...

Страница 9: ...ricant to drainage pipe and limber pipe to ensure a smooth installation 4 48mm 58mm 48mm 58mm Long Screw Lubricant Small Leak proof Gasket Inlet Pipe Drainage Pipe Big Leak proof Gasket 5 Install the...

Страница 10: ...ip 2 1 A B 1 2 Mask Break Water Board Slot A A Slot B B Hinge Ear Detent E Faceplate Installation E 2 When tighten four locknuts on supporting board adjust to OPEN mark as shown 2 OPEN Supporting Boar...

Страница 11: ...o top 5 Faceplate Faceplate Supporting Board Lock 6 It is ready to use when connected to water supply after installation 6 Half Flush Button Full Flush Button Installation For In wall Tank Without Fra...

Страница 12: ...e it is a must to keep the tank level Connect the inlet hose with tank inlet pipe Note 1 Ensure water tank internal valve is OFF 2 Suggestion connect a temporary rubber or plastic hose on valve flush...

Страница 13: ...rp Knife Mask 6 When finishing the brickwork eliminate unwanted part of the mask the drainage pipe and the inlet pipe 6 Inlet Pipe Drainage Pipe REMOVE AND MAINTENANCE OF THE OUTLET VALVE REMOVE AND M...

Страница 14: ...EN to take out the supporting board 3 OPEN Locknut Supporting Board 4 Take out the supporting board as shown 4 5 Take out the break water board 5 Supporting Board Mask Break Water Board Slot A A Slot...

Страница 15: ...ly Turn on off the water supply by turning the valve 8 9 Take out the bracket as shown 9 Valve On Off Bracket 10 Loosen the filter nut as shown and then take out the inlet valve 10 Nut Filter Loosen T...

Страница 16: ...13 Outlet Valve 14 Remove discharge valve as shown and then take valve out for cleaning or adjusting 14 Outlet Valve 16 A Wash Filtration Net Close corner valve first then loosen and take out the tigh...

Страница 17: ...e is block by waste Wash the floating box with clean water No drainage when pressing the heavy and slight drainage button Too high or too low water level Leak of the toilet and squat Toilet does not f...

Страница 18: ...18 A B A B 1263048 T01 C...

Отзывы: