INSTALLING DOOR PANEL
A.
Insert a pivot pin into the top bracket
hole.
B.
Lift the door panel and position door
handle magnet toward strike jamb
magnet.
C.
From inside shower, place door panel
bottom block’s farthest hole from door
handle down over bottom bracket pin.
Be sure not to place side frame of door
panel down over pin.
D.
Pull top bracket pivot pin up and align
the top block’s farthest hole from door
handle with the top bracket hole and
insert pin through bracket hole and into
the block hole.
E.
Loosen the block screws and slowly
close door panel and slide blocks in top
and bottom frames so that door closes
with approximately 3/16
″
clearance
from edge of strike jamb. Make sure
that the bottom of door panel does not
rub on the bottom track seal.
F.
Tighten the block screws.
G.
For final adjustment, loosen the strike
expander jamb screws.
H.
Align the strike expander jamb with the
door panel handle frame with a 3/16
″
gap at top and bottom of the door
panel.
I.
Tighten the strike expander jamb
screws.