Troubleshooting Guide
Symptoms
Probable Cause
Recorrective Action
1. The unit does
not operate.
A. No electric current flow
through the unit.
A. Check the connection of
the wire to the correct
terminals or not.
B. The circuit breaker or
fuses are cut off.
B. The circuit breaker has
drop down to “OFF”
position. Push it to “ON”
position.
C. There is not sufficient
water pressure.
C. Improve water pressure.
2. Water is not
heated as
desired.
A. There is too much water
pressure/volume into the
unit.
A. Decrease the water
supply by adjusting the
inlet valve and stop valve.
3. The water
temperature
remains
unstable.
A. The water pressure
remains unstable.
A. Adjust water pressure.
4. The water does
not flow well
while the water
from the other
tap are strong.
A. The filter is obstructed
by dust.
A. Clean the filter.
B. The shower head is
clogged.
B. Clean the showerhead.
5. Shower cycles
from hot to cold.
A. Handshower is blocked.
A. Remove and clean.
B. Water pressure is below
the minimum pressure
required for the unit
operation.
B. Make sure that the mains
supply and/or the stop
valve is fully turned on.
C. Temperature control
knob is set too high.
C. Turn the temperature
control knob counter-
clockwise until a cooler
temperature is achieved.
D. The thermostat is faulty
or damaged.
D. Replace.
Kohler Co.
17 1237889-X2-G