7
7.9
Section 7
Electrical System and Components
Starter Disassembly
1. Remove the hex nut and disconnect the positive
(+) brush lead/bracket from the solenoid terminal.
2. Remove the three screws securing the solenoid to
the starter. See Figure 7-10.
Figure 7-10. Removing Solenoid Screws.
NOTE:
Test procedure for checking starter solenoid
on pages 7.16 and 7.17.
Torx Head Screws
Figure 7-11. Solenoid Removed from Starter.
3. Remove the two thru (larger) bolts. See Figure
7-12.
Figure 7-12. Removing Thru Bolts.
4. Remove the commutator end plate assembly,
containing the brush holder, brushes, springs,
and locking caps. Remove the thrust washer from
inside the commutator end. See Figure 7-13.
Figure 7-13. Removing Commutator End Plate
Assembly.
5. Remove the frame from the armature and drive
end cap. See Figure 7-14.
Figure 7-14. Starter Frame Removed.