ROUGHING-IN

PACKAGING LIST

PACKAGING LIST

UNIT : mm

Kohler reserves the right to change marked dimensions without prior notice.

Reference Value

225

1.5

160

1.5

10

1

69.5

1.5

80.8

1.5

M8 2 core male connector cable to connect power
M8

M8 3 core female connector cable to conncet air pump
M8

S/No. Material No.

Material Description
English

Material Description
Chinese

Unit

1
2
3
4

6

7

8

5

1306552-*
1297096
1331845-T01
1331845-T8

1331137
1331114 or
1331117
1331139

1059169/
1284513/
1284514

Beam Sensor Faceplate
Positioning Plate
Installation Instruction
Service Parts Page

Pump Control Module Assy
Transformer Assy
220v or 110v
Carton Individual

Fixed Tube/
Fixation Plate/
Screw

220V

110V

/
/

1pcs
1pcs
1pcs
1pcs

1pcs

1pcs

1set

4pcs/
4pcs/
4pcs

A: Transformer Installation

Warning:

Before the in wall tank is installed, the transformer is installed
on the wall first. (It is recommended to place transformers on
the ceiling or other hidden and easy to operate places.) As
illustrated, the output connector of transformer (with 2 core
female connector) through the bushing pipe (the bushing pipe
dia.

16~

20 is recommended) into water tank. Connect

the input terminal of transformer(black) with power supply
220V/110V AC. Customer can use the PVC pipe for wiring.
See figure

Don't mistake the input and output terminal,

or it may cause damage to the product. Insulation
measures must be taken at the connection. Otherwise,
short-circuit current may occur and damage the
transformer.

A

(

2

)

16~

20mm)

AC220V/110V

Output AC 6V

AC6V

Input AC 220V/110V (Black)

AC220V/110V (

)

Transformer Assy.

Ceiling

Bushing Pipe

Low-voltage AC

Transformer Output
Connector (In Tank)

(

)

1331845-T01-B

Содержание BEAM K-23056T

Страница 1: ...in the tank Kohler will not be responsible for any damage related to above mentioned cleanser or solvent Do not apply spares that are not provided by Kohler and please note that glass adhesive tape shall not be applied to the installation of Kohler spares Kohler will not be responsible for any damage related to installation with spares not provided by Kohler Region SKU number SKU Rated voltage Rat...

Страница 2: ...set 4pcs 4pcs 4pcs A Transformer Installation Warning Before the in wall tank is installed the transformer is installed on the wall first It is recommended to place transformers on the ceiling or other hidden and easy to operate places As illustrated the output connector of transformer with 2 core female connector through the bushing pipe the bushing pipe dia 16 20 is recommended into water tank C...

Страница 3: ...sh Air Hose Input Signal Cable Input Signal Cable Rib A A Slot A A Slot B B Rib B B 5 Install air pump assembly needs attention the slot of faceplate and the rib of air pump needs install properly to correspond A A B B Prevent installation improperly See figure 6 Connect big flush air hose and half flush hose to outlet joint in air pump assembly Connect power output cable of transformer and power ...

Страница 4: ...he installation hole size of 201 X 136 mm See figure 8 The installation of mask 4 holes with diameter of 10mm and depth of 16mm are needed to be reserved at the locating hose Drill 10mm holes through air hose on the side of mask See figure 7 1 7 20mm 80mm 201 X 136 mm 8 4 10mm 16mm 10mm 2 0 2 0 2 0 2 0 At least 80mm gap reserved 80mm Air hose Pinch plate Finished wall Supporting Board 7 20mm recom...

Отзывы: