5
22
18
24
23
1248990-2A-B
2
1248990-2A-B
3
INSTALLATION CHECKOUT
Ensure that all connections are tight. Ensure that the handle is in the off position.
Open the drain. Turn on main water supply and check for leaks. Repair as
required.
Remove aerator(28) by key(27). Turn the faucet handle on and run hot and cold
water through spout about one minute to remove any debris. Remove any debris
from aerator. Shut faucet off and reinstall aerator.
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could
adversely affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
27
28
INSTALLATION
How to Install the Spout
If needed to take off the hoses to repair, reinstall and
tighten them by hand. Install the mounting studs(2)
onto the faucet body base(3). Insert lift rod(5) to the
hole at the rear of the body. Slide the washer(4) over
the flexible hoses(1) and mounting studs, and into
the groove at the bottom of the faucet body.
Insert the faucet assembly into the lavatory hole.
Position the faucet. From underside of the lavatory,
place the brackets(6, Rubber washer is on the top)
onto the mounting studs. Tighten the nuts(7) by
wrench(8) to secure the faucet.
Attach the hoses to water supplies. The hose with
"COLD" label connects to cold water.
How to Install the Drain
Remove stopper(11), flange(10), washer(9) and
tailpiece(25) from drain body(13). Supply enough
tape or sealant to tailpiece thread. Reinstall the
tailpiece. Insert drain body kit into the lavatory from
underside, and make sure the drain lever hole(14)
facing to the back of the lavatory. Screw the flange
with washer into the drain body. Tighten the
locknut(15) by hand from the underside of the fixture.
NOTE:
If needed, apply a ring of plumbers putty
around the underside of the drain flange(10), instead
of using washer(9).
Place stopper(11) into drain body aligning the flat
side of stopper hole(12) with the drain lever hole.
How to Install the Lift Rod Kit
Select the connection of the drain and the lift rod
according the dimension of lavatory.
Way 1: Select the latch(19)
Insert the ball lever rod(18) into the bigger
hole(21) of the latch(19). Insert the lift rod into the
other hole of latch. Push the ball lever rod down
to the open position. Tighten the screw(20) on
the latch.
17
14
18
16
19
5
18
15
19
20
21
26
18
25
15
Way 2: Select the link kit(24, 22 & 23).
According to the lift rod length, bend the link(22).
Connect the link onto ball lever rod with "V" clip(23).
Slide lift rod(5) into the hole on link. Push the ball lever
rod(18) down to the open position. Tighten thumb
screw(24).
How to Install the Drain Shroud
Slide drain shroud(26) with slot facing toward the
back, up over tailpiece(25) and around ball lever
rod(18), until contact with locknut(15) on the drain.
NOTE:
At this point, tighten the drain shroud.
Connect the tailpiece to the trap. The tailpiece
should extend 25mm to 40mm into the trap.
Apply Plumbers Putty
2
3
1
4
5
8
6
7
11
12
9
10
10
13
15
14
25
Remove the latch(19) and retaining nut(16). Fit the
plastic washer(17) and retaining nut onto the ball
lever(18). Insert the ball lever assembly into the drain
lever hole and through the stopper hole. Tighten the
retaining nut.
Be sure that the ball lever(18) points to the back of the
lavatory, tighten the locknut(15) on the drain body by
wrench.
NOTE:
Do not reposition the drain if plumbers putty
applied after the locknut is tightened, or you may break
the putty seal. Wipe away excess plumbers putty.
⑥
④
③
⑤
①
②
Ø58
Ø36.5
Ø31.75
97.5
110
135
176.5
97348T-4
130
Ø68
Ø38
Ø43 66
27
393
263
312
Ø32~Ø38
45 Max.
Ø51
173
148
3.5°
G1/2˝