8

1418436-T01-A

常见故障排除

以下部分故障现象可通过指示灯闪烁情况识别。(参考“感应指示灯的各种闪烁情况”)

   现    象

原    因 

  处理方法

不出水

(感应指示灯不闪烁)

感应指示灯闪烁
不出水

感应指示灯闪烁
出水量小

角阀关闭
起泡器脏堵过
滤装置堵塞

角阀是否彻底打开
过滤装置堵塞
起泡器脏
水压太低

打开角阀
清洗过滤装置
清洗起泡器
检查供水系统

 打开角阀

清洗起泡器
清洗过滤装置

检查电池
移开物体
清洁窗口
检查接线端
打开把手

感应指示灯每

2

秒快速

闪烁

1

次而不出水

更换电池
重新连接接插件

电池耗尽

把手未打开

接线端未接插好

如按以上操作仍未解除故障,请与销售商或科勒(中国)投资有限公司联系。

除安装更换电池外,请勿随意拆卸龙头其它部件。

Following faults shall be identified by sensor flashing (refer to “Various flashing condition of sensor”). 

Symptoms 

Probable causes

Recommended Action

Sensor quick flashes once 
approximately every 2 
seconds, no water flow. 

Contact dealer or Kohler (China) investment Co., Ltd. if above failure is not dismissed. 
Do not dismantle parts of the faucet randomly except battery installation or replacement. 

TROUBLE SHOOTING 

No water flow 
(sensor does not flash)

No battery or reversed battery installation
Object in sensing range
Dirty sensing eye
Improper or wrong wiring 
Handle is not open

Check battery
Remove the objects
Clean sensing eye
Check terminals
Open handle

Batteries run out
Improper plug in method

Replace batteries
Reconnect connector

Turn on angle valve
Clean aerator
Clean filter 

Open angle valve
Clean filter
Clean aerator
Check incoming water supply

Angle valve is off 
Aerator is dirty and plugged
Filter clogged

Does angle valve fully open 
Filter clogged
Dirty aerator
Supply pressure is low

Sensor flashing 
No water flow. 

Sensor flashing 
Low flow

Содержание ALEUTIAN K-28555T-CP

Страница 1: ...le water 2 Do not apply strong force and impact to the product to avoid failure and water leakage 3 Recommended operation pressure for sprinkler 2 5bar 4 Max operation pressure for sprinkler 0 5MPa 5bar Install a pressure relief valve if water pressure over 0 5 Mpa 5bar Max working temp and ambient temp of the sprinkler 60 C Pay special attention to keep the sprin kler away from heater otherwise p...

Страница 2: ...4分钟 自动止水 环境温度 1 55 进水温度 0 5 60 适用水压 0 05 0 86MPa 花洒适用水压 0 2 0 5MPa 冷热水管 混水管 Power DC 2 piece of AA size alkaline batteries LR06 2 Inspection Duration 0 35s Turn off Delay of valve 0 35s Overtime Water Control Auto stop water supply over 4min Ambient Temperature 1 55 Supply Water Temperature 0 5 60 Supply Water Pressure 0 05 0 86Mpa Applicable Water Pressure for Sprinkler 0 2 0 5Mpa TECHNICAL PARAM...

Страница 3: ...basin secure locking nut 16 on drainage body Remove excess plumbers putty Note after securing anchor nut do not adjust drainage body position otherwise the sealing property will be damaged Insert lift rod assembly 23 into the rear side hole of water outlet cross hole of connecting rod 25 Connect connecting rod to spheri cal rod 19 by V shape clip 26 manually tighten bolt 24 to connecting rod Push ...

Страница 4: ...led to the wall 4 How to install the sensor assembly Install washer 34 into the bottom groove of the sensor assembly 33 then insert the sensor assembly with washer into mounting hole on the wash basin adjust the sensor assembly waving mark on the top From under the wash basin slide the washer 36 washer 37 and installation ring 38 into main body 35 Secure installation ring locking screw 39 on the s...

Страница 5: ...ater to run through the spout for about 1 minute to remove debris Remove battery box assembly unscrew screws 47 and install two AA batteries 49 per mark direction on the battery box covers 48 and then secure battery box cover 48 and screws 47 Place battery box assembly into the groove designed for valve box At last connect red green wire on the solenoid valve to corresponding wire on probe assembl...

Страница 6: ...adjust water outlet height When approaching hand to sensing range above the sensor head water flow out from the faucet water flows a press A as shown water b flows press B as shown water stops flow Remove shower head and pull hose out when holding shower head 52 is needed Note do not pull with too much force or pull the hose too long to avoid any damage on hose and connector How to clean water dra...

Страница 7: ... ing and organic solvents on the sensing eye c Do not impact sensing eye CLEANING INSTRUCTION 1 Various flashing condition of sensor Sensor is the effective and only way for customer to understand the induction faucet Understand the meaning of sensor flashing will help customer use induction faucet properly as shown 1 Quick flash indicates induction faucet is in 2 minutes automatic adjusting cycle...

Страница 8: ...t Co Ltd if above failure is not dismissed Do not dismantle parts of the faucet randomly except battery installation or replacement TROUBLE SHOOTING No water flow sensor does not flash No battery or reversed battery installation Object in sensing range Dirty sensing eye Improper or wrong wiring Handle is not open Check battery Remove the objects Clean sensing eye Check terminals Open handle Batter...

Страница 9: ...产品时 环保使用期限 才有效 10 产品中有害物质含量的说明 注 本表格提供的信息是基于供应商提供的数据及科勒公司的检测结果 本产品应用环保设计理念 在当 前技术水平下 所有有害物质或元素的使用已经控制到了最低程度 科勒公司会继续努力通过改善现有技 术来减少这些物质的使用 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572现行有效版本规定的限量要求以下 表示有害物质至少在该部件的某一均质材料中的含量超出GB T 26572现行有效版本规定的限量要求 表示部分机型含有该部件 Reclaim Indication 10 Note d ...

Отзывы: