background image

1. How to install faucet

Secure bolts (2) to the bottom of the water 
outlet (1). Insert water inlet assembly into 
wash basin installation hole. Install washer 
(3), steel washer (4) and nut (5) from the 
bottom of the wash basin. Align water outlet 
position, wrench (10)-tighten to secure water 
outlet assembly by locking nut (5). 

Remove flex hose (6) protection, slide into 
guiding sleeve (7), and then attach guiding 
sleeve on anchor bolt (2). 

Cross flex hose (6) through weight (8), and 
connect to hose (9) . 

2. How to install the water drain

Remove flange (13) from the drain body 
(15), attach washer (14) from the bottom of 
flange. Insert drain from the bottom of the 
wash basin drainage rod opening (17) 
towards the rear direction, screw the flange 
into drainage body; tighten locking nut (16) 
from the bottom manually. Insert stopper 
(11) into water drainage body. Adjust the 
end of the stopper hole (12) and align it to 
drainage rod opening.

Note: 

apply sealant putty to the underside of 

the flange (13) if needed, instead of using 
washer (14).  

Install rubber washer (18) into drainage rod 
opening, then slide another rubber washer 
(20) and anchor bolt (21) on the long end of 
spherical rod (19). Insert into drainage rod 
opening and stopper, secure anchor nut.

Ensure spherical rod toward rear wash 
basin, secure locking nut (16) on drainage 
body. Remove excess plumbers putty. 

Note: 

after securing anchor nut, do not 

adjust drainage body position, otherwise the 
sealing property will be damaged.

Insert lift rod assembly (23) into the rear side 
hole of water outlet, cross hole of connecting 
rod (25). Connect connecting rod to spheri-
cal rod (19) by V-shape clip (26), manually 
tighten bolt (24) to connecting rod.

Push spherical rod downward to drain full 
opening position, and then adjust lift rod 
position, so to make the lift rod head (22) 
about 10mm away from the installation 
platform. Manually tighten thread.

Connect tailpiece (27) to water outlet elbow.

3

1418436-T01-A

INSTALLATION STEPS

安装步骤

1

、如何安装出水口

将固定螺栓

(2)

装入到出水口组件

(1)

底部,将出水口组件插入脸盆安装
孔中。从脸盆下方将垫片

(3)

、钢垫

(4)

和螺母

(5)

装到出水口组件上。调

整出水口组件的位置,用扳手

(10)

紧螺母

(5)

,固定出水口组件。

去掉软管

(6)

的保护套,将软管放入

软管导向套

(7)

内,再将导向套装到

固定螺栓

(2)

上。

将软管

(6)

穿过重锤

(8)

与软管

(9)

连接。

2

、如何安装排水器

将法兰盘

(13)

从排水本体

(15)

取下,

在法兰盘底部套上垫片

(14)

。将排水

本体从底下插入洗脸盆,排水杆口

(17)

朝向后方,把法兰盘旋入排水本

体中,从下方用手拧紧锁紧螺母

(16)

把止水塞组件

(11)

放入排水本体中,

调整止水塞使止水塞末端的洞口

(12)

靠近并对正排水杆的洞口。

注意:

如果需要,可直接在法兰盘

(13)

底面沿周围涂上一圈密封油灰,

而不使用垫片

(14)

将橡胶垫片

(18)

装进排水杆的洞口里,

再把另一个塑料垫片

(20)

和固定螺母

(21)

套进球动杆

(19)

长的一端。把球

杆组件插入排水球杆的洞中并穿过
止水塞,拧紧固定螺母。

确保球动杆指向脸盆后方,拧紧排
水本体上的锁紧螺母

(16)

,去除多余

油灰。

注意:

在锁紧螺母锁紧后,不可调

整排水本体的位置,否则会破坏油
灰密封。

1

2

4

9

7
6
8

10

5

3

13

12

14

16

15

17

11

18

20

21

19

16

将提拉杆组件

(23)

插入到出水口后侧

孔中,并穿过联杆

(25)

的孔。用

V

(26)

将联杆接到球动杆

(19)

上,把

手捻螺丝

(24)

装到联杆上。

将球动杆往下推到排水器全开位置。
调整提拉杆的高度,使提拉杆头

(22)

底部距离安装台面

10mm

左右。拧紧

手捻螺丝。

把尾管

(27)

连接到去水弯管上。

24

22

25

26

27

19

23

Содержание ALEUTIAN K-28555T-CP

Страница 1: ...le water 2 Do not apply strong force and impact to the product to avoid failure and water leakage 3 Recommended operation pressure for sprinkler 2 5bar 4 Max operation pressure for sprinkler 0 5MPa 5bar Install a pressure relief valve if water pressure over 0 5 Mpa 5bar Max working temp and ambient temp of the sprinkler 60 C Pay special attention to keep the sprin kler away from heater otherwise p...

Страница 2: ...4分钟 自动止水 环境温度 1 55 进水温度 0 5 60 适用水压 0 05 0 86MPa 花洒适用水压 0 2 0 5MPa 冷热水管 混水管 Power DC 2 piece of AA size alkaline batteries LR06 2 Inspection Duration 0 35s Turn off Delay of valve 0 35s Overtime Water Control Auto stop water supply over 4min Ambient Temperature 1 55 Supply Water Temperature 0 5 60 Supply Water Pressure 0 05 0 86Mpa Applicable Water Pressure for Sprinkler 0 2 0 5Mpa TECHNICAL PARAM...

Страница 3: ...basin secure locking nut 16 on drainage body Remove excess plumbers putty Note after securing anchor nut do not adjust drainage body position otherwise the sealing property will be damaged Insert lift rod assembly 23 into the rear side hole of water outlet cross hole of connecting rod 25 Connect connecting rod to spheri cal rod 19 by V shape clip 26 manually tighten bolt 24 to connecting rod Push ...

Страница 4: ...led to the wall 4 How to install the sensor assembly Install washer 34 into the bottom groove of the sensor assembly 33 then insert the sensor assembly with washer into mounting hole on the wash basin adjust the sensor assembly waving mark on the top From under the wash basin slide the washer 36 washer 37 and installation ring 38 into main body 35 Secure installation ring locking screw 39 on the s...

Страница 5: ...ater to run through the spout for about 1 minute to remove debris Remove battery box assembly unscrew screws 47 and install two AA batteries 49 per mark direction on the battery box covers 48 and then secure battery box cover 48 and screws 47 Place battery box assembly into the groove designed for valve box At last connect red green wire on the solenoid valve to corresponding wire on probe assembl...

Страница 6: ...adjust water outlet height When approaching hand to sensing range above the sensor head water flow out from the faucet water flows a press A as shown water b flows press B as shown water stops flow Remove shower head and pull hose out when holding shower head 52 is needed Note do not pull with too much force or pull the hose too long to avoid any damage on hose and connector How to clean water dra...

Страница 7: ... ing and organic solvents on the sensing eye c Do not impact sensing eye CLEANING INSTRUCTION 1 Various flashing condition of sensor Sensor is the effective and only way for customer to understand the induction faucet Understand the meaning of sensor flashing will help customer use induction faucet properly as shown 1 Quick flash indicates induction faucet is in 2 minutes automatic adjusting cycle...

Страница 8: ...t Co Ltd if above failure is not dismissed Do not dismantle parts of the faucet randomly except battery installation or replacement TROUBLE SHOOTING No water flow sensor does not flash No battery or reversed battery installation Object in sensing range Dirty sensing eye Improper or wrong wiring Handle is not open Check battery Remove the objects Clean sensing eye Check terminals Open handle Batter...

Страница 9: ...产品时 环保使用期限 才有效 10 产品中有害物质含量的说明 注 本表格提供的信息是基于供应商提供的数据及科勒公司的检测结果 本产品应用环保设计理念 在当 前技术水平下 所有有害物质或元素的使用已经控制到了最低程度 科勒公司会继续努力通过改善现有技 术来减少这些物质的使用 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572现行有效版本规定的限量要求以下 表示有害物质至少在该部件的某一均质材料中的含量超出GB T 26572现行有效版本规定的限量要求 表示部分机型含有该部件 Reclaim Indication 10 Note d ...

Отзывы: