Kohler 12RESL Скачать руководство пользователя страница 25

TP-6517 1/11

25

Section 3 Scheduled Maintenance, 12 kW Models

3.4 Spark Plugs

Reset the spark plug gap or replace the plugs with new
plugs as necessary.

1. Clean the area around the base of the spark plug to

keep dirt and debris out of the engine.

2. Remove the spark plug and check its condition.

Replace the spark plug if it is worn or if its reuse is
questionable.

3. Check the spark plug gap using a wire feeler

gauge. Adjust the gap to 0.76 mm (0.030 in.) by
carefully bending the ground electrode.

See

Figure 3-4 and Figure 3-5.

1--514

Figure 3-4

Checking the Spark Plug Gap

1--511

Figure 3-5

Adjusting the Spark Plug Gap

3.5 Air Cleaner Element and

Precleaner

The engine has a replaceable high-density paper air
cleaner element with an oiled foam precleaner. See
Figure 3-6.

Check for a buildup of dirt and debris around the air
cleaner system. Keep this area clean.

Note:

Operating the engine with loose or damaged air
cleaner components could allow unfiltered air
into the engine causing premature wear and
failure.

1

2

3

4

5

6

7

586536

1. Cover knob
2. Air cleaner cover
3. Element cover nut
4. Element cover

5. Foam precleaner
6. Air cleaner element
7. Air cleaner base

Figure 3-6

Air Cleaner Components

Содержание 12RESL

Страница 1: ...Residential Commercial Generator Sets Models 12RESM1 12 18RESL Controller DC RET Digital Control TP 6517 1 11d Operation...

Страница 2: ...eadily available for future reference Record field installed kit numbers after installing the kits Generator Set Identification Numbers Record the product identification numbers from the generator set...

Страница 3: ...r Set 16 2 4 2 Stopping Generator Set 17 2 5 Exercising Generator Set 17 2 6 Faults 17 2 6 1 Shutdowns 17 2 6 2 Warnings 17 2 6 3 Resetting Controller after a Fault Shutdown 17 2 7 Battery Charger 19...

Страница 4: ...e Oil Recommendation 33 4 3 4 Oil Change Procedure 33 4 3 5 Oil Cooler 34 4 4 Spark Plugs 34 4 5 Air Cleaner Service 35 4 6 Cooling System 35 4 7 Exhaust System 36 4 8 Battery 36 4 9 Battery Charger 3...

Страница 5: ...r set or connected equipment disable the generator set as follows 1 Move the generator set master switch to the OFF position 2 Disconnect the power to the battery charger 3 Remove the battery cables n...

Страница 6: ...tainer when removing the fuel line or carburetor Combustible materials A fire can cause severe injury or death Generator set engine fuels and fuel vapors are flammable and explosive Handle these mater...

Страница 7: ...set transfer switch and related equipment and electrical circuits Turn off the main circuit breakers of all power sources before servicing the equipment Never contact electrical leads or appliances w...

Страница 8: ...NING Servicing the exhaust system Hot parts can cause severe injury or death Do not touch hot engine parts The engine and exhaust system components become extremely hot during operation Notice NOTICE...

Страница 9: ...he prescribed intervals Obtain service from an authorized service distributor dealer to keep equipment in top condition Nameplate The following illustration shows a typical generator set nameplate Cop...

Страница 10: ...eadquarters Europe Middle East Africa EMEA Kohler Power Systems 3 rue de Brennus 93200 Saint Denis France Phone 33 1 49 178300 Fax 33 1 49 178301 Asia Pacific Power Systems Asia Pacific Regional Offic...

Страница 11: ...sign and full pressure lubrication for maximum power torque and reliability under all operating conditions D Dependable maintenance free electronic ignition D Precision formulated cast iron constructi...

Страница 12: ...eld connection terminal block location 11 Spark plug locations both sides 12 Oil drain hose 13 Oil drain valve 14 Oil filter 15 Exhaust 16 Equipment ground 17 Battery charger 18 DSAI lead location 19...

Страница 13: ...2 RS 232 connector for application program updates 13 Engine starting battery location battery purchased separately 14 Oil drain hose 15 Nameplate location on base 16 Oil drain valve 17 Exhaust outlet...

Страница 14: ...TP 6517 1 11 14 Section 1 Features Notes...

Страница 15: ...ct the exhaust system components for cracks leaks and corrosion D Check for corroded or broken metal parts and replace them as needed D Check that the exhaust outlet is unobstructed Oil Level Maintain...

Страница 16: ...dark and battery draw is minimized A remote start signal from a transfer switch or a remote start stop switch connected to controller leads 3 and 4 reactivates the controller Moving the generator set...

Страница 17: ...y items restricting the air flow 2 6 Faults 2 6 1 Shutdowns Under the fault shutdown conditions listed in Figure 2 3 the generator set shuts down automatically and the controller displays a fault code...

Страница 18: ...is sensed during cranking Shuts down 3 seconds after the fault is detected OF Overfrequency shutdown Shutdown occurs when the governed frequency exceeds 110 of the system s frequency setpoint for mor...

Страница 19: ...process Figure 2 5 Charging Method Display Operating Condition Red ON Green OFF When the red LED is on it indicates the battery is discharged and the battery charger is recharging at the BULK rate st...

Страница 20: ...TP 6517 1 11 20 Section 2 Operation Notes...

Страница 21: ...evere injury or death Do not work on the generator set until it cools WARNING Servicing the exhaust system Hot parts can cause severe injury or death Do not touch hot engine parts The engine and exhau...

Страница 22: ...m Tighten control and power wiring connections X Yearly Remote control system if equipped X Monthly Visible wear or damage X Quarterly Wire abrasions where subject to motion X X Six Months Wire cable...

Страница 23: ...dation Use API American Petroleum Institute Service Class SG SH or SJ synthetic oil Synthetic oil oxidizes and thickens less than other oils and leaves the engine intake valves and pistons cleaner Sel...

Страница 24: ...heck the oil level Add oil to bring the level up to the F mark on the dipstick 4 Check for leaks a Check for oil leaks b Fix leaks and recheck the oil level c Reinstall the housing side panel 3 3 5 Oi...

Страница 25: ...e Figure 3 4 and Figure 3 5 1 514 Figure 3 4 Checking the Spark Plug Gap 1 511 Figure 3 5 Adjusting the Spark Plug Gap 3 5 Air Cleaner Element and Precleaner The engine has a replaceable high density...

Страница 26: ...ning knob and remove the cover 5 Remove the element cover nut element cover and the paper element with precleaner 6 Remove the precleaner from the paper element Note Do not wash the paper element or c...

Страница 27: ...has ceased Flush the resulting liquid with water and dry the area Battery gases Explosion can cause severe injury or death Battery gases can cause an explosion Do not smoke or permit flames or sparks...

Страница 28: ...T 115 VAC 50 60Hz 1 6A OUTPUT 12 VDC 6 Amps MAX BAT 180 Amp Hr Max DATE 6 AMP AUTOMATIC BATTERY CHARGER R C US LISTED BATTERY CHARGER 53AB 2608KH 1 1 LED indicators 2 Mounting flanges 3 AC power cord...

Страница 29: ...ator set master switch in the OFF RESET position 3 11 3 Cylinder Lubrication 1 Remove the spark plugs 2 Pour one tablespoon of engine oil into each spark plug hole Install the spark plugs and ground t...

Страница 30: ...TP 6517 1 11 30 Section 3 Scheduled Maintenance 12 kW Models Notes...

Страница 31: ...ator set until it cools WARNING Servicing the exhaust system Hot parts can cause severe injury or death Do not touch hot engine parts The engine and exhaust system components become extremely hot duri...

Страница 32: ...mote control system if equipped M Visible wear or damage Q Wire abrasions where subject to motion 6 months 6 months Wire cable insulation condition 3Y or 500 Engine and Mounting Visible wear or damage...

Страница 33: ...Oil Check 4 3 3 Engine Oil Recommendation Use 5W 30 API American Petroleum Institute Service Class SG SH or SJ synthetic oil Synthetic oil oxidizes and thickens less than other oils and leaves the en...

Страница 34: ...bris See Figure 4 2 for the oil cooler location The oil cooler is located under the No 2 cylinder shroud Remove the top mounting screw and loosen the two side screws then lift off the cylinder shroud...

Страница 35: ...nt or damaged 4 When servicing the air cleaner check the air cleaner base and latch Make sure it is secured and not bent or damaged Also check the element cover for damage or improper fit Replace all...

Страница 36: ...Battery gases can cause an explosion Do not smoke or permit flames or sparks to occur near a battery at any time particularly when it is charging Do not dispose of a battery in a fire To prevent burns...

Страница 37: ...RY CHARGER 53AB 2608KH 1 1 LED indicators 2 Mounting flanges 3 AC power cord 2 5 2 3 4 4 Fuse 5 Battery leads 12 VDC Figure 4 8 6 Amp Float Equalize Battery Charger 4 10 Circuit Protection If the gene...

Страница 38: ...ne stops 4 Place the generator set master switch in the OFF RESET position 4 11 3 Cylinder Lubrication 1 Remove the spark plugs 2 Pour one tablespoon of engine oil into each spark plug hole Install th...

Страница 39: ...ection 2 6 If a fault code is displayed identify and correct the cause of the fault condition Then reset the controller See Section 2 6 3 Problem Possible Cause Corrective Action Controller LED displa...

Страница 40: ...re insufficient Check the fuel supply and valves Engine malfunction Contact the distributor dealer No AC output AC circuit breaker in the OFF position Place the circuit breaker in the ON position AC c...

Страница 41: ...off all DC equipment while charging Red and green LEDs stay on for more than 24 hours Onboard DC systems are drawing between 1 5 and 5 amps Turn off all DC equipment while charging One or more inopera...

Страница 42: ...TP 6517 1 11 42 Section 5 Troubleshooting Notes...

Страница 43: ...ter s Laboratories CUL Canadian Underwriter s Laboratories cu in cubic inch cw clockwise CWC city water cooled cyl cylinder D A digital to analog DAC digital to analog converter dB decibel dB A decibe...

Страница 44: ...ersize overspeed OSHA Occupational Safety and Health Administration OV overvoltage oz ounce p pp page pages PC personal computer PCB printed circuit board pF picofarad PF power factor ph phase PHC Phi...

Страница 45: ...Notes...

Страница 46: ...Notes...

Страница 47: ......

Страница 48: ...CO Kohler Wisconsin 53044 Phone 920 457 4441 Fax 920 459 1646 For the nearest sales service outlet in the US and Canada phone 1 800 544 2444 KohlerPower com Kohler Power Systems Asia Pacific Headquart...

Отзывы: