Safety Information

1.  Care should be taken when drilling into walls and floors to avoid any hidden 

pipes or wires.

2.  We strongly recommend that all glass panels are moved by a minimum of two 

people and that any protective packaging along the glass edges is kept in place 

for as long as possible to prevent damage before installation.

3.  Wear protective footwear when lifting panels.
4.  Wear safety glasses when drilling.

General

1.  Read all of these instructions and retain this guide for later use.

2.  Pass on this guide in the event of change of ownership of the installation site.

3.  Follow all warnings, cautions and instructions contained in this guide.

4.  Remove all protective tape from the enclosure before installation.
5.  Excessive flow rates may lead to overflowing and leaking.
6.  Water Spray may extend beyond the entrance of walk-in enclosures and we 

recommend tiling of the adjacent area.

7.  We recommend a drainage test is carried out to ensure the waste is adequate 

for the flow delivered.

8.  Doors that open outwards may drip water onto floor, ensure the floor covering 

will not be affected by water.

9.  Walk ins and divider panels are designed to minimise water escaping outside 

the enclosure but by their very nature are not fully water tight.

Introduction

General Information

Thank you for purchasing a quality Mira product. To enjoy the full potential of your 

new product, please take time to read this guide thoroughly, having done so, keep 

it handy for future reference.
The following pages aim to provide comprehensive installation instructions, plus 

advice on how to care and maintain your product.
We recommend that the unit is installed by a qualified plumber or engineer.

Содержание Ascend Series

Страница 1: ...1 1317134 W2 B These instructions must be left with the user Installation Guide Frameless Quadrant Enclosure...

Страница 2: ...flow rates may lead to overflowing and leaking 6 Water Spray may extend beyond the entrance of walk in enclosures and we recommend tiling of the adjacent area 7 We recommend a drainage test is carried...

Страница 3: ...1 The wall channels must be installed onto a tiled or waterproof finished flat and even wall surface Failure to do so will result in an unsatisfactory seal which may cause property damage 2 We recomme...

Страница 4: ...4 1317134 W2 B Domestic Light Commercial Heavy Commercial Healthcare Recommended Usage Tools Required 6 0 mm...

Страница 5: ...134 W2 B Pack Contents X 8 q X 8 q X 1 q X 1 q X 1 q 4 0 mm 3 0 mm X 2 q X 8 q Top Carriers Bottom Carriers Glass lintel brackets and covers X 2 q X 2 q X 2 q X 2 q X 4 q X 8 q X 4 q X 2 q X 2 q X 2 q...

Страница 6: ...6 1317134 W2 B X 2 q X 2 q X 2 q X 1 q X 1 q X 1 q X 1 q A...

Страница 7: ...7 1317134 W2 B X 1 q X 1 q B...

Страница 8: ...tallation Note Make sure that the walls have been tiled down to the tray Make sure the Tray is leveled Make sure the walls are flat and square a Install the shower tray in accordance with the manufact...

Страница 9: ...890 890 20 1000 x 800 970 770 990 790 20 1000 x 1000 970 970 990 990 20 1200 x 900 1170 870 1190 890 Door Configuration Table ALWAYS AS BELOW 900 X 900 Opens towards curved larger panel 1000 X 1000 O...

Страница 10: ...the wall and partially install the fixing screws Ensure that the screw head spacers are fitted to the screws e Apply silicone sealant according to the manufacturers instructions along the length of t...

Страница 11: ...sition the wall channel on the wall and partially install the fixing screws e Apply silicone sealant according to the manufacturers instructions along the length of the wall and at the bottom of the w...

Страница 12: ...covers onto all the carriers e To aid assembly later place the assembled door inside the enclosure tray area lean carefully against wall x2 Note The door on the enclosure is reversible and can be alt...

Страница 13: ...e glass panel as illustrated b Push gaskets onto the glass and up to glass lintel bracket to get your measurement 12 mm as shown c Remove glass lintel bracket for later use 5 Prepare the fixed panels...

Страница 14: ...Make sure proper alignment of the two glass panels and the bottom rail along the tray f Make sure that glass panels are set inside L shape bracket g Insert the glass lollipops spacers 1 with serratio...

Страница 15: ...and tighten the two screws on each side c Using a spirit level make sure that both glass panels are upright and the top lintel is level d Screw the two glass lintel brackets into place onto the top l...

Страница 16: ...and measure the level a b 0mm c Support packers for top lintel level After positioning the top lintel with the cutouts on the glass you need to ensure the level before fully tightening the two screws...

Страница 17: ...arting at the bottom and working upwards b Make sure that both the glass panels are level and equal about the tray 0 mm Important Wet the beading seal to help with installation Note Prior to beading e...

Страница 18: ...required loosen the bolts and move the carriers up or down on the glass when the desired position is achieved re tighten the bolts f Once all adjustments have been made ensure the door edges are vert...

Страница 19: ...Apply the supplied lubricant within the trackway of the lintel at the 3 spots detailed above Move the door left and right to distribute the lubricant a Fit anti jump strip on the top lintel VIEW FROM...

Страница 20: ...20 1317134 W2 B 11 Handle Installation 2 0 mm a c b Note Handle installations are the same for all the handle options...

Страница 21: ...21 1317134 W2 B 12 a Fit the 3 vertical seals as shown above Door Closing vertical Seal Rear door vertical seal Inline panel vertical seal...

Страница 22: ...1317134 W2 B 13 a Apply sealant in accordance with the sealant manufacturers instructions along the outside surfaces of the door frame only b Allow the silicone sealant to cure for 24 hours before us...

Страница 23: ...leansers expressly specified for chrome Care To preserve the beauty of your shower enclosure for many years please observe the following care instructions Rinse glass and frame with clear water after...

Страница 24: ...24 1317134 W2 B Spare Parts 1 2 3 3 7 9 6 4 5 4 2 5 1...

Страница 25: ...Enclosure Parts Pack 3 4 1922 057 Spare Glazing Bead Pack 4 4 1922 096 Spare Quad Seal Pack 5 4 1922 095 Spare Quad Carriers Pack 6 4 1922 099 Spare Quad Anti Jump 7 4 1922 141 Spare Fixing Pack 8 4 1...

Страница 26: ...26 1317134 W2 B Notes...

Страница 27: ...27 1317134 W2 B Declaration of Performance...

Страница 28: ...B Kohler Mira Limited August 2018 18 Kohler Mira Ltd Cromwell Road Cheltenham Gloucestershire GL52 5EP UK KOHLER Mira Ascend Composed Shower Enclosures Bath Screens Declaration of Performance CE 0120...