Display cycle setting (SET8)
Use this setting to configure the display cycle.
Adjustment setting (SET9)
Configures the adjustment setting.
Press
□
Press
□
1 second later
Return to
Use
△
or
▽
key to select
the smoothing setting
from the list below.
<Smoothing setting>
: No smoothing (factory setting)
: 4 times
: 8 times
: 16 times
* Usually, it is not necessary to configure SETA - SETC.
Error Indicators
Indicator
Meaning
Required action
The sensor head of the
selected channel is not
connected or has been
disconnected.
In the case of disconnection,
turn off power and replace the
sensor head.
Invalid scaling setting.
Reconfigure the scaling setting
so it satisfies the required
scaling conditions.
Over voltage being applied to
sensor input.
After correcting for the source
of the problem, hold down the
MODE key for more than one
second.
Over voltage being applied to
switch output.
n
(n: applicable channel)
* For other information, detailed specifications, and precautions, see the product
catalog.
* For inquiries about the product, contact your nearest Koganei sales office or the
Overseas Group noted below.
OVERSEAS GROUP
3-11-28, Midori-cho, Koganei City, Tokyo 184-8533, Japan
Tel: 042-383-7271 Fax: 042-383-7276
❽
❼
Use
△
or
▽
key to select
the display refresh cycle
setting from the list below.
<Display cycle setting>
: 100 ms (factory setting)
: 250 ms
: 500 ms
: 1000 ms
Press
□
Press
□
1 second later
Return to
Switch output inversion setting (SET4)
This setting can be used to invert the switch output of each channel.
Setting CH is displayed
CH1 to 4: Select the setting CH
Use
△
or
▽
key to select
the setting CH.
Reverse the setting of the
switch output. The indicator
corresponding to the setting
CH blinks.
Use
△
or
▽
key to select the switch
output reverse mode from the list below.
<Switch output reverse mode>
: No reverse (Factory setting)
: Reverse
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
The set value is displayed for 1 second.
1 second later
1 second later
1 second later
1 second later
1 second later
Return to
Return to
Sensor head LED indicator light setting SET5)
Configure the sensor head LED indicator display range setting
The sensor head LED indicator turns on within the effective measuring range with the factory setting.
Configure the upper limit
of the sensor head LED
indicator display range.
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Configure the lower limit
of the sensor head LED
indicator display range.
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Scaling setting (SET6)
Configure the display scaling.
No change after scaling for the analog output (1-5V).
※※※
※※※
※※※
※※※
SCAL: Scaling setting
INIT: Scaling initialization
Configure scaling point 1.
Move the cylinder to scaling
point 1 (A1)
Move the cylinder to the display
value (B1) of scaling point 1.
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Configure scaling point 2.
Move the cylinder to scaling
point 2 (A2)
Move the cylinder to the
display value (B2) of scaling
point 2.
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Return to
Return to
Return to
|
A1-A2
|
/
|
B1-B2
|>
=1
The scaling setting is initialized and
a value of 0 to 1000 is displayed.
△
or
▽
Backlight display setting (SET7)
Use this setting to configure backlight color settings.
Use
△
or
▽
key to select
the backlight color setting
from the list below.
[Backlight color setting]
: Backlight OFF
: When switch output OFF: Green When switch output ON: Red (factory setting)
: When switch output OFF: Red When switch output ON: Green
: Always green
: Always red