Main unit
DTY-ELG21
Order codes
AC adapter (accessory)
Rating
input : AC100
〜
240V
50/60Hz 0.58A
Output : DC24V 1A
Cable length: 300 mm
DTRY-ZEM-G11
NOTE : For ELG11/21 air gun type only
●Options (sold separately)
Replacement tungsten discharge needle (unit: 5 per set)
Special tool for replacing discharge needle
NOTE: Only bits are for sale.
AC Adapter (300mm)
Replacement nozzle
DTRY-ELB21
DTY-ZN1-G21
6.35
9
22
φ4.5
Shape of jig for replaceable bit
Main unit
Cable length :3000 mm
Replacement of discharge needle
When replacing the discharging needle, use the dedicated tool DTRY-ELB21 in combination with a torque driver.The dedicated tool is designed not
to damage the discharge needle or the threaded part of the main body. Replacing with another tool may cause damage to the discharge needle and
main body, etc.The tightening torque for replacement should be 15 to 20N·cm.If the discharge needle is replaced without using the dedicated tool
and the discharge needle, main body, etc. are damaged, the warranty will not cover.
NOTE: When replacing the nozzle or take off the nozzle for the maintenance of the discharge needle, tighten the nozzle securely by hand without
using a tool.
■
Static charge removal characteristics
■
Flow characteristics
0
0.1
0.2
0.3
0.4
0.5
0.6
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Air pressure [MPa]
Static charge removing time [sec]
Measuring distance :50mm
Static charge removing time for supplied air pressure
0.6
0.5
0.4
0.3
0.2
0.1
0
0
100
200
300
400
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
供給エア圧力(MPa)
除電時間
(秒)
測定距離:50mm
Air pressure [MPa]
Flow rate [L/min] (ANR)
DTRY-ZPS-G11
Note 1:Measured using a 150 mm, 20pF charged plate monitor.
Note 2:The static charge removing time is the decay time from
± 1000 V to ± 100 V.
Note 3:The above data are actual measurement valve and are
not guaranteed.
※
Be sure to read the safety precautions (common to the
ionizers) and handling instructions and precautions
(common precautions) on the website prior to using
the product.
※
DReplacement nozzle
only for DTY-ELG21
1
●
Do not point the tip of the nozzle at a person.
●
Use safety glasses and earplugs because blowing air could blow
objects into peopleʼs eyes or cause hearing loss.
Warning
NOTE: The above data are actual measurements and are not guaranteed.