Koehler K2269X Скачать руководство пользователя страница 7

K2269X Low Temperature Pressure Viscometer 

Operation and Instruction Manual 

 

K2269X-Manual

    

 

-

3-

 

2  Safety Information and Warnings 

 

Safety 

Considerations. 

The 

use 

of 

this 

equipment  may  involve 

hazardous 

materials  and 

operations.  This  manual  does  not  purport  to 
address all of the safety problems associated with 
the use of this equipment. It is the responsibility of 
any  user  of  this  equipment  to  investigate, 
research,  and  establish  appropriate  safety  and 
health  practices and  determine  the applicability of 
regulatory limitations prior to use. 

 
Equipment  Modifications  and  Replacement 
Parts. 

Any  modification  or  alteration  of  this 

equipment from that of factory specifications is not 
recommended  voids  the  manufacturer  warranty, 
product safety, performance specifications, and/or 
certifications  whether  specified  or  implied,  and 
may result in personal injury and/or property loss. 
Replacement  parts  must  be  O.E.M.  exact 
replacement equipment. 
 

Unit  Design. 

This  equipment  is  specifically 

designed for use in accordance with the applicable 
standard  test  methods  listed  in  section  1.2  of  this 
manual. The use of this equipment in accordance 
with  any  other  test  procedures,  or  for  any  other 
purpose,  is  not  recommended  and  may  be 
extremely hazardous. 
 

Chemical Reagents Information. 

Chemicals and 

reagents  used  in  performing  the  test  may  exhibit 
potential  hazards.  Any  user  must  be  familiarized 
with  the  possible  dangers  before  use.  We  also 
recommend  consulting  the  Material  Data  and 
Safety  Sheet  (MSDS)  on  each  chemical  reagent 
for  additional  information.  MSDS  information  can 
be 

easily 

located 

on 

the 

internet 

at 

http://siri.uvm.edu 

or 

http://www.sigma-

aldrich.com. 
 

3  Getting Started 

 

The  instructions  for  preparing  the  equipment 

assume  that  the  user  is  aware  of  the  contents  of 
this  document, which lists the warranty conditions 
and important precautions.

 

 

3.1  Packing List

 

 

  K2269X Low Temperature Pressure Viscometer 

  K2269X-Manual 

Operation 

and 

Instruction 

Manual 

 
 
 
 

Refer to Figure 1 for an illustration of the included 
accessories below: 

  Set of Interchangeable Pressure Gauges 

(A)

 

Consisting of: 
- 311-060-005 Pressure Gauge 0-60 psi 
- 311-100-004 Pressure Gauge 0-100 psi 
- 311-600-004 Pressure Gauge 0-600 psi 
- 311-503-001 Pressure Gauge 0-5000 psi 

 

 

K226-0-22 Set of S/S Capillary No. 1-8 

(B)

 

Consisting of:  
- K226-0-22/1 Capillary, #1 
- K226-0-22/2 Capillary, #2 
- K226-0-22/3 Capillary, #3 
- K226-0-22/4 Capillary, #4 
- K226-0-22/5 Capillary, #5 
- K226-0-22/6 Capillary, #6 
- K226-0-22/7 Capillary, #7 
- K226-0-22/8 Capillary, #8 

 

 

K226-0-21 Copper Gasket (Qty 8) 

(D)

 

 

 

265-000-001

 

Thermocouple (Qty 3) 

(E) 

 

 

K22690-0-27 Grease Cylinder Assembly  
(Qty 3) 

(F)

 

Includes:  
- K22690-0-8 Grease Cylinder Piston 
(Qty 3) Packed Separately 

(C) 

 

 

K22690-23150 Calibration Pipe Assembly 

(G)

 

 

 

K22690-23151 Standard Pipe Assembly 

(H)

 

 

 

K22690-03100 Cylinder Holder Removal Tool 

(I)

 

 

 

Set of Wrenches and Tools (7 Pieces) 

(J)

 

 

 

 

Figure 1. Packing List 

 
 
 
 

Содержание K2269X

Страница 1: ...enue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis...

Страница 2: ......

Страница 3: ...tured in conformance with the applicable standards set forth in this certification Specifications ASTM D1092 This unit is tested before it leaves the factory to ensure total functionality and complian...

Страница 4: ......

Страница 5: ...tion 5 4 1 Instrument Descriptions 5 4 2 Top Assembly Description 5 4 3 Control Box Descriptions 6 4 4 Gear Box and Motor Descriptions 7 4 5 Temperature Controller Descriptions 7 5 Operation 9 5 1 Ref...

Страница 6: ...pport of your laboratory testing needs Our products are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument servi...

Страница 7: ...t may exhibit potential hazards Any user must be familiarized with the possible dangers before use We also recommend consulting the Material Data and Safety Sheet MSDS on each chemical reagent for add...

Страница 8: ...e unit and all accessories for damage If any damage is found keep all packing materials and immediately report the damage to the carrier We will assist you with your claim if requested When submitting...

Страница 9: ...ar pump gears drive motor required to power the hydraulic system Refer to section 4 4 for detailed descriptions on this section of the apparatus 4 2 Top Assembly Description Figure 3 Instrument Descri...

Страница 10: ...nect the grease cylinder to the hydraulic system This port is also used as the main connection point for the hydraulic system calibration by utilizing the Calibration Pipe Assembly See Figure 1 Item G...

Страница 11: ...n See Figure 4 item 13 Variable Speed Motor is coupled to the speed reducer and is capable of operating at two speeds required to simulate flow rates attained by 40 tooth gear and 64 tooth gear as per...

Страница 12: ...a certified calibrated measuring device to acquire the temperature Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two t...

Страница 13: ...ion instructions for the temperature controller NOTE Allow for the test chamber to cool and come to temperature equilibrium prior to turning on Drive Motor Recirculating Pump See Figure 4 Item 13 It m...

Страница 14: ...imed 11 Once a steady flow or constant drip rate is observed the hydraulic system is primed and free of air bubbles 12 Using the relief valve at the right hand side of the calibration piping assembly...

Страница 15: ...esting purposes If not attached ferrule will be in thermocouple packaging 3 Remove bottom cap from Grease Cylinder F 4 Invert grease cylinder and place Grease Cylinder Piston C inside Grease Cylinder...

Страница 16: ...cylinder loading procedure is now complete Before attaching a capillary changing the flow of the hydraulic fluid and starting a test the sample grease must attain temperature equilibrium with the test...

Страница 17: ...may result in personal injury or death If you have any questions about maintaining your equipment then please do not hesitate to contact the Koehler technical service department 6 1 Routine Maintenan...

Страница 18: ...104 002 Fuse 25A Slo Blo 5X20 M M 220 240 013 Cartridge Heater 500W 240V 265 500 001 RTD Temperature Probe x 12 275 103 044 Temperature Controller 100 240V 288 230 018 Motor 208 230V 3 Phase 288 230 0...

Страница 19: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 15 7 Wiring Diagrams 7 1 220 240V 50Hz Unit Wiring K22695...

Страница 20: ...e the return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the re...

Страница 21: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 17 Notes...

Страница 22: ...K2269X Low Temperature Pressure Viscometer Operation and Instruction Manual K2269X Manual 18 Notes...

Отзывы: