Kodiak SXA1900HX Скачать руководство пользователя страница 9

8

  

Battery charger (SXB2800HX,SXB4000HX,SXB5500HX(S),SXB7000HX(S) only)

          The DC terminal is used only for charging 12 volt batteries. It provides up to 
          12V-8.3A(100W) of maximum power.

Operation

CAUTION:

Be sure to make correct connection to the battery. 
The po) battery terminal should be connected to the "

red

terminal.

Do not

 over-charge the battery. 

Over-charging

 of a battery can result in 

personal injury due to 

explosion

 of battery.

Stopping Operation

  

In an emergency:

      

(Please refer to the Honda Owner’s manual)

      To stop the engine in an emergency, move the engine switch to the "

off

” position.

  

In normal use:

 

1.  Turn the “

no-fuse

” breaker to the “

0

” position.

 

2.  Unplug all appliances.

 

3.  Move the engine switch to the “

off

” position.

 

 

4.  Turn the fuel valve to the “

off

 “position.

Never leave an appliance plugged into the generator when you 
stop the generator, as damage could result to the generator and/or 
appliance.

NOTICE

Maintenance & Storage

  

Maintenance (Please refer to the Honda Engine Owners Manual):

      

Periodic inspection and adjustment of the Honda engine are essential if a high level of

     performance is to be maintained.  Regular maintenance will also ensure a long service 
     life.  The required service intervals and kind of maintenance to be performed are 
     described in the Honda Engine Owner’s Manual. Please refer to the Honda Engine 
     Owner’s Manual for more details.

 

Transportation/Storage (Please refer to the Honda Engine Owners Manual):

     

When transporting the generator, turn the fuel cock OFF and keep the unit level 

     to prevent fuel spillage.
     When the generator is in storage for a long period, carry out the following maintenance. 
     Please refer to the Honda Owner’s manual. 
 

1.   Store generator in a well-ventilated, low humidity area.
2.   Clean each part with an oil permeated rag.
3.   Change the engine oil.
4.   Clean the air cleaner.
5.   Empty the gasoline from fuel tank.
6.   Start and run engine until the it runs out of fuel.

Never use water to clean the generator

!

WARNING

!

WARNING

Содержание SXA1900HX

Страница 1: ...sed Owner s Manuals Carefully read all Warnings Safety Precautions Assembly and Operating Instructions Maintenance and Storage information Introduction 1 Features Speci cations 1 Safety Precaution 2 3...

Страница 2: ...r obligation Features Specifications SXA1900 SXA2800 SXB2800 SXB4000 SXB5500 SXB7000 Honda OHV Engine Full Frame Protection Oil Alert Automatic Idle Control Voltmeter Voltage Regulator DC Output No Fu...

Страница 3: ...ING a DO NOT refuel the generator while it is in operation or still hot b DO NOT refuel while smoking or near ames pilot lights sparking electrical devices etc e g power tools welders or grinders Unit...

Страница 4: ...ile in operation It could cause overheating and result in equipment damage 4 For storage do not cover unit until the engine has cooled completely 5 Ambient temperature should not exceed 100o F 40o C N...

Страница 5: ...engine is running at normal speed useable AC power is available Diagram 2 Starting the engine Applying AC load single voltage type Refer to Diagrams 3 4 5 1 Place generator s no fuse breaker switch in...

Страница 6: ...it automatically If the no fuse breaker switch trips during operation the generator is either over loaded or the appliance is defective Check the appliance and or generator for overloading or defect m...

Страница 7: ...n the 0 position 3 Start engine Please refer to the Honda Engine Owner s Manual 4 Allow the engine to warm up for 2 3 minutes before connecting tools or appliances 5 Insert the plug of the electrical...

Страница 8: ...tch 12V DC Output Engine ON OFF Switch Output Voltage Meter Power On Indicator Light Output voltage selector switch 4 wire Twist lock receptacle NEMA L14 30R No Fuse Breaker Tee Slot GFCI Receptacle 1...

Страница 9: ...erator and or appliance NOTICE Maintenance Storage Maintenance Please refer to the Honda Engine Owners Manual Periodic inspection and adjustment of the Honda engine are essential if a high level of pe...

Страница 10: ...persists please contact your local Honda dealer Engine Symptom CAUSE REMEDY Engine fails to start Fuel level is low Re ll fuel tank making sure not to over ll Oil Level is low Fill oil to proper leve...

Страница 11: ...10 Troubleshooting If problem persist please call the Kodiak toll free hot line below for the service center nearest you Customer Service Hotline 1 800 461 1323 Visit our website www kodiakpower ca...

Страница 12: ...2005 4 GENERATOR PARTS CATALOG MODEL GESXB5500HX S CSA 4500VA 120 240V 60Hz No GESXB5500HX S...

Страница 13: ...03011 HEX BOLT W FLANGE M10 1 25 250 1 11 GESGK3403015 HEX BOLT W FLANGE M6 1 0 165 4 12 GESG19B30908020 HEX BOLT W FLANGE M8 1 0 20 4 13 GESG19B30905012 HEX BOLT W FLANGE M5 0 8 12 2 14 GESG19B509080...

Страница 14: ...14 GESG15111583000 D C TERMINAL BLACK 1 15 GESG15400141000 NO FUSE BREAKER DC 10A 1 16 GESG85321072000 LEAD WIRE ASSY AUTO THROTTLE 1 17 GESG15111585020 FUSE 1A 1 18 GESG15400142000 TWIN NO FUSE BREA...

Страница 15: ...X NUT W FLANGE M6 1 36 GESG19S00903012 CROSS RECESSED HEAD SCREW M3 12 2 37 LENS ASSY PROTECTOR 1 HONDA PART 38 GESG32343 892 003 KNOB CONTROL LEVER 1 HONDA PART 39 GESG36106 892 003 BUSH CONTROL KNOB...

Страница 16: ...25 1 0t 10 GESG16950 ZB4 0150 COCK COMP FUEL 1 11 GESG90854 ZB2 0000 RUBBER FUEL TUBE 1 12 GESG95001 45150 40 TUBE FUEL 13 GESG95002 02080 CRIP B8 TUBE 14 GESG15350202000 CASE CONTROL 15 GESG19B30906...

Страница 17: ...STOPPER DISCHARGE GURD 6 GESG19B30906012 HEX BOLT W FLANGE M6 1 0 12 7 GESG15500377000 BONDING WIRE 8 GESG19W50906000 TOOTH LOCK WASHER 6 9 GESG19B30906020 HEX BOLT W FLANGE M6 1 0 20 10 GESG19W009060...

Отзывы: