
4
Operation
Starting the engine
:
1. Read Honda Engine Owner’s Manual.
2. Open fuel cock.
3. Set choke lever towards the “
close
” position when engine is cold.
If engine is warm, choke lever should be moved to the "
Open
” position.
4. Set the engine switch to the “
run
” position.
5. Pull on starter rope with a fast steady pull to start the engine. (Diagram 2)
6. After engine has started, move the choke
lever back gradually to the “
Open
” position.
7. Once the engine is running at normal
speed, useable AC power is available.
Diagram 2:
Starting the engine.
Applying AC load (single voltage type) (Refer to Diagrams 3, 4, 5.)
:
1. Place generator’s “
no fuse breaker
” switch in the “
0
" position.
2. Start engine (Please refer to the Honda Engine Owner’s Manual.)
3. Allow the engine to warm up for 2 - 3 minutes before connecting tools
or appliances.
4. Insert the plug of the electrical appliance into the “
AC receptacle
”.
5. Place generator’s “
no fuse breaker switch
” in the “
1
” position.
6. Reset the GFCI receptacle.
Diagram 3:
SXA1900HX AC Panel
Tee Slot GFCI Receptacle
“Power On” Indicator Light
No Fuse Breaker
Ground Terminal