10
TROUBLESHOOTING
Symptom
Probably Cause(s)
Corrective Action
Pump running normally but
low pressure at nozzle.
Unloader valve has not been
properly set
Make sure unloader is
adjusted properly
e
l
z
z
o
n
n
r
o
W
Incorrect nozzle being used
Black Side Handle on Dual
lance is on chemical injection
setting
If the nozzle is worn, replace
it.
Make sure nozzle is matched
to the flow and pressure of
the pump.
With lance facing away from
you, turn the Black Side
Handle all the way in a
clockwise rotation
Pressure drops after period of
normal use
Nozzle worn
Check and replace nozzle
Pump producing chattering
noise
Pump sucking air
Check that hoses and fittings
are air tight
Pulsating when gun is off.
Leaks downstream of
unloader
Nozzle plugged
Nozzle being used may be too
small
Check for leaks downstream
of the unloader valve.
If no leaks, unloader may
have to be serviced
Remove obstruction
Replace with properly sized
nozzle
Fluctuating Pressure while
spraying
Pump sucking air
Check that hoses and fittings
are air tight
Water in crankcase
No soap injection
High humidity in the air
Worn packings
Black Side Handle on the
Dual lance is not on the
chemical injection setting
Change oil intervals.
Replace packings
With the dual lance pointed
away from you, rotate the
Black Side Handle on the
Dual lance all the way in a
counter clockwise rotation
Gas Engine
Engine will not start.
Low fuel level
Low oil level
Add fuel
Add oil