MDS-1100R Series
Chapter 3 Installation
0092642260-01
3-7
3.4.2 4kW Open Antenna unit (242J159098x: RB806_MDS-1104R)
1. Confirm that the power of the Radar unit is turned off.
Remove the front and back covers of the Scanner unit by loosening fixing bolts.
2. Remove the TR unit by disconnecting the connector X1 and X2 after loosening two fixing bolts of
the TR unit. Please make sure magnetron does NOT touch metals.
3. Remove the cable holder plate and the rubber packing by loosening two bolts at the bottom of the
Scanner unit box.
4. Antenna cable shall be taken into the Scanner unit box through the cable inlet hole.
5. Antenna cable shall be fixed as described in the illustration below, using the cable holder plate and
the rubber packing removed in 4. Shield braid terminal shall be fixed under the cable holder plate
together with lug terminal, after removing the edge portion of heat contraction tube of the antenna
cable.
6. Mount the TR unit after connecting the X1 and X2 connectors (removed in 2) by fixing bolts.
7. 7 pin connector shall be connected to X11 of the TR unit, 9 pin connector to X12.
8. Antenna cable shall be clamped onto the TR unit. Please make sure the antenna cable does NOT
touch magnetron and magnetron lead wires.
9. The front and back covers of the Scanner unit shall be fixed by fixing bolts.
4kW (RB806
)
(RB716A
)
(RB716A
)
cable clamp
X12
X11
X1
X2
Fixing bolt
TR unit
Magnetron lead wire
cable clamp
X1
X2
X11
X12
magnetron
Cut portion of Scanner unit base
Fixing bolt
Shield braid terminal
Cable holder plate
Scanner unit
Antenna cable
Put the shield braid
under the cable holder plate
as short as possible.
7-pins connector
Shield braid
9-pins connector
Remove the heat contraction tube
Rubber packing
Cable inlet hole
Make the height less than 5mm
TR unit
Содержание MDS-1100R Series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 8: ... This page intentionally left blank ...
Страница 12: ... This page intentionally left blank ...
Страница 16: ... This page intentionally left blank ...
Страница 24: ... This page intentionally left blank ...
Страница 62: ... This page intentionally left blank ...
Страница 67: ...MDS 1100R Series Chapter 5 Maintenance 0092642260 01 5 5 RB806 RB807 717A Unit mm inch ...
Страница 68: ...Chapter 5 Maintenance MDS 1100R Series 5 6 0092642260 01 RB808 718A RB809 719A Unit mm inch ...
Страница 69: ...MDS 1100R Series Chapter 5 Maintenance 0092642260 01 5 7 MDS 11R Unit mm inch ...
Страница 70: ......