![Koden MDC-2000BB Series Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/koden/mdc-2000bb-series/mdc-2000bb-series_operation-manual_1984746035.webp)
MDC-2000BB Series
Chapter 1 Basic Operation
0093120012-01
1-10
1.10 Setting of OFF CENTER
When viewing widely in the heading, use this
function.
Setup: OFF, ON (Initial value: OFF)
1
Press the [OFF CENT] key
2
Change the setting of [OFF CENTER] to
[ON] with the [ ] and [ ] keys.
It moves to the off center position where the
own ship point is stored
OFF CENTER
OFF
ON
3
Press the [ ] key.
4
Move the cursor to the point you desire to
move your ship with the [ ], [ ], [ ] [ ]
keys.
5
Press the [ENT] key.
Own ship’s position moves to the position of
the cursor.
●
The movable range is limited.
(See the movable range shown below.)
●
When [PPI/PPI] or [PPI/NAV] is selected in
[DISPLAY SELECT] and TM is selected in
[MODE], the off-center cannot be executed.
1.11 Setting of Enhance
(Enlarged Target)
If a target is too small to see, the target can be
enlarged to make it easier to see it.
Setup: OFF, 1, 2 (Initial value: OFF)
1
Press the [ENH] key, the enhance value
changes.
2
The greater the numeral is, the larger the
target is enlarged.
1.12 EBL
This mode is used when measuring the bearing
from own ship to a target.
Setup: OFF, ON (Initial value: OFF)
1
Press the [EBL] key.
2
The EBL rotates clockwise with the [ ] key
and counterclockwise with the [ ] key.
The bearing indicated by the EBL is shown
at the lower left side of the display.
1.13 VRM
This mode is used when measuring a distance
from own ship to a target.
Setup: OFF, ON (Initial value: OFF)
1
Press the [VRM] key.
2
The VRM moves in the far direction with the
[ ] key and in the near direction with the [ ]
key.
The distance indicated by the VRM is shown
at the lower right side of the display.
34%
66%
Own ship
relocatable
area
Own ship
Содержание MDC-2000BB Series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ... This page intentionally left blank ...
Страница 25: ... This page intentionally left blank ...
Страница 27: ...MDC 2000BB Series Chapter 1 Basic Operation 0093120012 01 1 2 ...
Страница 96: ... This page intentionally left blank ...
Страница 103: ...MDC 2000BB Series Chapter 6 Attached Table 0093120012 01 6 7 RB804 Unit mm inch Weight 8 3kg 18 3lb ...
Страница 106: ... This page intentionally left blank ...
Страница 111: ......
Страница 112: ......