KDS-6000BB
Chapter 2 Adjustment
0092660002-06
2-1
Chapter 2 Adjustment
2.1 Setup of frequency of Transducer
unit
On KDS-6000BB, the frequencies can be
set in a range of 130 to 210 kHz.
2.1.1 Setting of frequency
1. Press to be displayed [Menu1].
2. Turn (knob/left) to select
[Freq select].
3. Press (knob/left) or to
move setting value box.
The setting value will be displayed in red
color box.
4. Turn (knob/left) to select
frequency.
5. Press to close the menu.
2.2 Setting of gain of Transducer unit
Gain (TD)
When the bottom cannot be detected or
when the bottom is of mud pool or seaweed,
[Gain (TD)] shall be turned up. When
transfer to fish schools, etc. frequently
occurs, [Gain (TD)] shall be turned down.
Adjustment shall be made under conditions
where the white line is displayed. To display
the white line, select [White line] in [Menu2].
At appropriate Gain (TD), the white line is
displayed on the sea bottom.
When sensitivity (TD) has increased too
much, the white line also moves to fish
school.
Menu1
Freq select
Dynamic range
Pulse width
TX power
Noise reduction
Color rejection
Background color
Image correct
130.0
26 dB
Middle
Auto
0 %
0
A-1
1
Color
Freq select
130.0
White line should have the same
thickness as the (darkest) color for the
strongest signal.
Содержание KDS-6000BB
Страница 1: ......
Страница 2: ......
Страница 18: ...External View KDS 6000BB xvi 0092660002 06 Remote controller RCW 14 Optional Unit mm inch...
Страница 19: ...KDS 6000BB External View 0092660002 06 xvii Hull unit DHU 630 Unit mm inch...
Страница 56: ...This page intentionally left blank...
Страница 60: ...This page intentionally left blank...
Страница 71: ......
Страница 72: ......