background image

6

KODAK ADVANTIX 100, 200, and 400 Films

 E-46

KODAK ADVANTIX 200 Film

Characteristic Curves

F002_0389AC

1.0

0.0

1.0

4.0

3.0

2.0

1.0

DENSITY

2.0

0.0

3.0

LOG EXPOSURE (lux-seconds)

R

G

B

Status M

Daylight 1/100 second

Densitometry:

Exposure:
Process: 
C-41

Spectral-Sensitivity Curves

1.0

*Sensitivity = reciprocal of exposure (erg/cm  ) required

LOG SENSITIVITY

250

300

*

0.0

550

WAVELENGTH (nm)

to produce specified density

350

400

500

450

650

600

2

700

750

2.0

3.0

4.0

Status M

0.2 above D-min

Density:

Process:

Effective Exposure:

Densitometry:

C-41

1/50 second

F002_0390AC

Yellow-

Forming

Layer

Magenta-

Cyan-

Forming

Layer

Forming

Layer

Spectral-Dye-Density Curves

F002_0391AC

700

2.5

1.5

2.0

0.5

1.0

DIFFUSE SPECTRAL DENSITY

600

WAVELENGTH (nm)

400

0.0

500

C-41

Typical densities for a midscale neutral subject

Process:

and D-min.

Midscale Neutral

Minimum Density

Содержание ADVANTIX 100

Страница 1: ...an record a variety of data including format selected i e classic HDTV group panoramic camera orientation illumination e g flash backlighting etc picture taker recorded data The magnetics are part of...

Страница 2: ...right film type in your camera for every picture taking situation It also allows you to separate your cassettes by photo subject If you use this feature the FSI will be at when you remove the cassett...

Страница 3: ...CPS beam candlepower seconds Guide Number Distances in Feet Metres ADVANTIX 100 ADVANTIX 200 ADVANTIX 400 350 40 12 60 18 85 26 500 50 15 70 21 100 30 700 60 18 85 26 120 36 1000 70 21 100 30 140 42 1...

Страница 4: ...FSI is at have your film processed promptly by a photofinisher that displays the logo shown above The photofinisher will return the film cassette with your prints your negatives will be inside the ca...

Страница 5: ...0 Yellow Forming Layer Forming Magenta Layer Forming Cyan Layer Spectral Dye Density Curves NOTICE The sensitometric curves and data in this publication represent product tested under the conditions...

Страница 6: ...m required LOG SENSITIVITY 250 300 0 0 550 WAVELENGTH nm to produce specified density 350 400 500 450 650 600 2 700 750 2 0 3 0 4 0 Status M 0 2 above D min Density Process Effective Exposure Densitom...

Страница 7: ...cess Effective Exposure Densitometry 1 100 second Status M 4 0 3 0 2 0 750 700 2 600 650 450 500 400 350 to produce specified density WAVELENGTH nm 550 0 0 300 250 LOG SENSITIVITY Sensitivity reciproc...

Страница 8: ...k System Available 24 hours a day 7 days a week Many technical support publications for Kodak products can be sent to your fax machine from the Kodak Information Center Call U S A 1 800 242 2424 Ext 3...

Отзывы: