background image

KODAK ADVANTIX 100, 200, and 400 Films

 E-46

5

KODAK ADVANTIX 100 Film

Characteristic Curves

LOG EXPOSURE (lux-seconds)

3.0

0.0

2.0

DENSITY

1.0

2.0

3.0

4.0

1.0

0.0

1.0

F002_0383AC

Status M

C-41

Daylight 1/500 second

Densitometry:

Exposure:
Process:

B

G

R

Spectral-Sensitivity Curves

F002_0384AC

0.2 above D-min

Density:

C-41

Process:

Effective Exposure:

Densitometry:

1/50 second

Status M

4.0

3.0

2.0

750

700

2

600

650

450

500

400

350

to produce specified density

WAVELENGTH (nm)

550

0.0

*

300

250

LOG SENSITIVITY

*Sensitivity = reciprocal of exposure (erg/cm  ) required

1.0

Yellow-

Forming

Layer

Forming

Magenta-

Layer

Forming

Cyan-

Layer

Spectral-Dye-Density Curves

NOTICE: The sensitometric curves and data in this publication represent product tested
under the conditions of exposure and processing specified. They are representative of
production coatings, and therefore do not apply directly to a particular box or roll of
photographic material. They do not represent standards or specifications that must be met
by Eastman Kodak Company. The company reserves the right to change and improve
product characteristics at any time.

Minimum Density

Midscale Neutral

and D-min.

Process:

Typical densities for a midscale neutral subject

C-41

500

0.0

400

WAVELENGTH (nm)

600

DIFFUSE SPECTRAL DENSITY

1.0

0.5

2.0

1.5

2.5

700

F002_0385AC

Содержание ADVANTIX 100

Страница 1: ...an record a variety of data including format selected i e classic HDTV group panoramic camera orientation illumination e g flash backlighting etc picture taker recorded data The magnetics are part of...

Страница 2: ...right film type in your camera for every picture taking situation It also allows you to separate your cassettes by photo subject If you use this feature the FSI will be at when you remove the cassett...

Страница 3: ...CPS beam candlepower seconds Guide Number Distances in Feet Metres ADVANTIX 100 ADVANTIX 200 ADVANTIX 400 350 40 12 60 18 85 26 500 50 15 70 21 100 30 700 60 18 85 26 120 36 1000 70 21 100 30 140 42 1...

Страница 4: ...FSI is at have your film processed promptly by a photofinisher that displays the logo shown above The photofinisher will return the film cassette with your prints your negatives will be inside the ca...

Страница 5: ...0 Yellow Forming Layer Forming Magenta Layer Forming Cyan Layer Spectral Dye Density Curves NOTICE The sensitometric curves and data in this publication represent product tested under the conditions...

Страница 6: ...m required LOG SENSITIVITY 250 300 0 0 550 WAVELENGTH nm to produce specified density 350 400 500 450 650 600 2 700 750 2 0 3 0 4 0 Status M 0 2 above D min Density Process Effective Exposure Densitom...

Страница 7: ...cess Effective Exposure Densitometry 1 100 second Status M 4 0 3 0 2 0 750 700 2 600 650 450 500 400 350 to produce specified density WAVELENGTH nm 550 0 0 300 250 LOG SENSITIVITY Sensitivity reciproc...

Страница 8: ...k System Available 24 hours a day 7 days a week Many technical support publications for Kodak products can be sent to your fax machine from the Kodak Information Center Call U S A 1 800 242 2424 Ext 3...

Отзывы: