A-61514 September 2004
25
3. Wipe the upper and lower transport areas with a roller cleaning pad.
4. Dry the transport area with a dry Staticide Wipe.
5. Push against the raised edge on the left side of the rear roller cover and
pull the cover up and out to remove it.
6. Remove any dust or debris under the rear drive roller cover.
7. Re-install the rear drive roller cover.
8. Go to the next section to clean the imaging guides.
Cleaning the
imaging guides
Clean the exposed (top side) surfaces of the imaging guides. You do not need
to remove the imaging guides for cleaning unless there is dust or dirt on the
underside of the imag
ing
guide. If you need to remove the imaging guides, follow
the instructions for “Installing the
Kodak
Imaging Guide Set for i100 Series
Scanners”.
1. Wipe the upper and lower imaging guides with a Staticide Wipe.
2. Dry the imaging guides with a dry Staticide Wipe.
3. Lower the scanner door and press it down firmly until it latches into place.
4. Go to the next section to clean the paper path.
Rear drive roller cover