background image

Inner line call to the newly installed house 

Picking up handset and pressing (inner line)          button, newly installed 

house is called out (call maintains for 30 seconds). 

Inner line LED is turned on (only if there

s no house on inner line). 

Newly installed house responds to the call, call maintains (for 3 minutes). 

(LED is turned off.) 

Hanging up handset, communication is ended. 

Inner line call from newly installed house 

If house received a call, tone sound rings in house handset (for 30 seconds) 

(inner line) LED flickers. 

Picking up handset, communication begins (maintains for 3 minutes). 

(When communication begins, LED is turned off). 

Hanging up handset, communication is ended. 

Call from guardroom to house

Call to guardroom for communication 

Operational Description

Pressing chime switch to call, chime tone of call from front door rings 

(device does not support communication function and only detects call state). 

Inner line call and communication 

chime tone of inner line call rings and communication maintains 

for 3 minutes (installation of additional monitors and interphones is required). 

Communication with lobby phone 

After chime tone rings, user can communicate with lobby phone 

for 3 minutes. (If pressing the door open button during the communication with lobby phone, opener 

installed common lobby door is opened.) 

Call to and communication with guardroom 

If pressing guard button on interphone, user can call to and communicate with guardroom. 

When a lobby calls to house in standby mode, tone sound rings for about 30 seconds in house. 

Speaker outputs tone sound and (lobby/guard) LED flickers. 

Picking up handset, communication with lobby is automatically available 

(available communication time: 3 minutes) (At this time, LED is turned off.) 

To open the door during the communication wit lobby, press door open button and opener will 

automatically operate. 

Hang up handset, communication is ended (call to lobby function is not available). 

If picking up handset and pressing guard/lobby                button, 

guardroom is called out (call maintains for 30 seconds). 

(When other house is not on the line, LED is turned on.) 

If guardroom responds to the call, call state is maintained (for 3 minutes). 

(When communication begins, LED is turned off.) 

If guardroom calls to house, tone sound rings in handset of house (for 30 seconds) and (guard/lobby) 

LED flickers. Picking up handset, communication begins (communication maintains for 3 minutes). 

At this time, LED is turned off. 

Hanging up handset, communication is automatically ended. 

Call from lobby

5-line polar wiring between wirings in main line of apartment unit 

6-line polar wiring between KVM-520 (monitor) and interphone 

2-line non-polar wiring in connection with chime switch at front door 

6-line polar wiring when installing more devices 

Functional Specification 

Wiring Specification 