5
6. Mounting the Bracket Holder
Can be attached either on the top or on the bottom. Assemble it with the
screws provided. (3 EA)
7. Auto iris lens connector
Please refer to page 13, 14 of this manual for the wiring specification.
8. Iris mode select switch
ES : Electronic auto iris, VI : Video iris, DC : DC Iris
ES mode is used with manual iris lenses. In ES mode the camera controls
the electronic shutter automatically from 1/50 to 1/100,000
sec.(PAL/CCIR)or 1/60 to 1/100,000 sec.(NTSC/EIA).
ES mode with a Manual iris lens is suitable for indoor surveillance. Select
the slide SW to the ES position.
For outdoor use, ES mode is not sufficient. In this case an Auto Iris lens of
either Video driven type or DC driven type is recommended. Move the slide
SW to VI position for the Video iris lens or move it to DC position for the DC
Iris lens. When VI or DC mode is selected, the electronic shutter speed is
fixed to 1/50sec(PAL/CCIR) or 1/60sec(NTSC/EIA).
9. DC Level control for DC Iris lens.
It is used for controlling the video output level of the DC driven auto iris
lens.
* To make the image brighter, turn the pot clockwise.
* To make the image darker, turn the pot counter clockwise.
1-1. 6 Way DIP Switch
DIP Switch configuration (24V AC LineLock, 230V AC LineLock only)
DIP Switch configuration (DC 12V only)
No.
1
2
3
4
5
6
OFF
=1.0
AGC Max : 26dB
BLC OFF
=0.45
AGC Normal : 20dB
BLC ON
OFF
ON
ON
OFF
(Phase Push SW up/down)Line Lock Mode
Manual White Balance
(Adjust the Push Button Up/Down)
Auto White Balance
(No need to Adjust the Push Button)
Internal Mode
ON
No.
1
2
3
4
5
6
OFF
=1.0
AGC Max : 26dB
BLC OFF
N.C
=0.45
AGC Normal : 20dB
BLC ON
N.C
OFF
ON
ON
OFF
Manual white Balance
(Adjust the Push Button Up/Down)
Auto White Balance
(No need to Adjust the Push Button)
ON
6
DC 12V
AC 230V Power Cord
DC 12V/AC 24V
Line Lock
1. 6Way Dip Switch
2. Power Input
Terminal
4. Power Indicator
3. Video Out Connector
(BNC Female)
5. Line Lock / White
Balance Push button
Back
-Color