ZOK-E/-Z
ZOK K14/0917
Page 53
The zero flow value for analogue output can be flexibly adjusted between the span of
4-20 mA using the menu item ‘0-Offset’.
This menu item works well for A-B function. The following table shows the function of
‘0-Offset’ with the input types available in the electronics:
Scaling
of
Analog
output
with
0
‐
Offset
For
A
‐
B
function
Output
current
(mA)
Flow
rate
display
(%FS)
0
‐
Offset
at
4
mA
Default
0
‐
Offset
at
8
mA
0
‐
Offset
at
12
mA
0
‐
Offset
at
16
mA
0
‐
Offset
at
20
mA
4
0
‐
25
‐
50
‐
75
‐
100
8
25
0
‐
25
‐
50
‐
75
12
50
25
0
‐
25
‐
50
16
75
50
25
0
‐
25
20
100
75
50
25
0
For
all
other
input
types
Output
current
(mA)
Flow
rate
display
(%FS)
0
‐
Offset
at
4
mA
Default
0
‐
Offset
at
8
mA
0
‐
Offset
at
12
mA
0
‐
Offset
at
16
mA
0
‐
Offset
at
20
mA
4
0
0
0
0
0
8
25
0
0
0
0
12
50
25
0
0
0
16
75
50
25
0
0
20
100
75
50
25
0
10.9.1 Analogue
output / Wiring type
While using analogue output, correct electrical wiring type must
always
be selected
.
Otherwise the offset value of 4.0 mA will not be correct.
10.10 Service
10.10.1 Service / User service
A Reset function and Blanking function for selected menu parameters are available for
user in Service menu. Together with the activation of a user password, certain device
functions and parameters for the user can be locked by a master user.
10.10.2 Service / User service / Change password
The default administrator user password is set to "00000", the user functions are thus
freely accessible. If the user's password has been changed from "00000", password
request will be generated on next entry to User menu.
If the default password has been forgotten or misplaced, the master password can be
requested from KOBOLD.
10.10.3 Service / User service / Factory defaults
By activating this function, the user can reset the device to factory settings. All user
settings will be lost and the device is now reset to the factory settings.
Содержание ZOK-ExK
Страница 19: ...ZOK E Z ZOK K14 0917 Page 19 Wiring for ZOK Zx with Supply option 0 and 6 ...
Страница 20: ...ZOK E Z Page 20 ZOK K14 0917 7 5 8 DOR with voltage pulse output DOR with Hall sensor output ...
Страница 24: ...ZOK E Z Page 24 ZOK K14 0917 Wiring for ZOK Z3 with Supply option 3 6 Wiring for ZOK Z3 with Supply option 0 6 ...
Страница 31: ...ZOK E Z ZOK K14 0917 Page 31 8 2 3 Display layout in measuring mode for dual channel ZOK Z1 E1 Z3 E3 ...
Страница 32: ...ZOK E Z Page 32 ZOK K14 0917 8 2 4 Display layout in measuring mode for dossier ZOK Z2 ...
Страница 57: ...ZOK E Z ZOK K14 0917 Page 57 ...
Страница 59: ...ZOK E Z ZOK K14 0917 Page 59 13 Dimensions ZOK ZxK ZOK Ex Zx ZOK ZxP ZOK ZxF ...