background image

User Guide - NCS2010

 

Banknote and Coin Counter 

NCS2010B Banknote and Coin Counter - Rev 23_09_2012 

Press to 

SWITCH ON

 

Press & hold to 

SWITCH OFF

 

Select required 

DENOMINATION

 

 

(Counter is empty)

 

Press to 

RESET CURRENT DENOMINATION

 

Press & hold to 

RESET

 

ALL

 

DENOMINATIONS

 

 

(Counter has banknotes or coins) 

Press to 

ABORT CURRENT COUNT

 

Select required 

COUNT MODE

 

5.0 CALIBRATION MENU      

Allow 5 minutes warm-up time (power on) before attempting calibration.

 

(In setup menu, change standby time to 10 

minutes to stop the counter from switching off. When finished, reduce standby time to save battery power) 
If red light is flashing, connect a charger and fully charge banknote and coin counter before attempting calibra-
tion. (Calibration should be performed while banknote and coin counter is running of battery power)

 

 

Place counter on a flat, stable surface. Do not lean or make contact with the surface during calibration. Make 
sure the room is free from strong air drafts caused by air conditioning or open windows 

To enter calibration menu, switch banknote and coin counter off and press ESC key. 

5.1 BANKNOTE AND COIN COUNTER CALIBRATION 

To maintain accuracy the counter can be calibrated at any time using a precise 100g weight (not included) 

Select CALIBRATE SCALES from calibration menu 

Start calibration and follow screen prompts. (ESC key can be used to abort calibration at any time) 

On completion, select one of two options: 

If any banknotes or coins were previously calibrated select CURRENT SETTINGS,  

otherwise select FACTORY DEFAULTS  

5.2 CALIBRATING SCOOP 

To use a different scoop to the one supplied, select CALIBRATE SCOOP

 

and follow screen prompts 

5.3 CALIBRATING PACKAGING ITEMS 

Calibration requires between 10 and 100 samples of packaging items such as elastic bands, paper clips, etc. 
(Use only elastic bands with consistent width and diameter. Paper rolls should be calibrated using paper from 
the smallest coin denomination) 

Select CALIBRATE PACKAGE from calibration menu and the type of package to be calibrated 

Select sample quantity to be used for calibration 

Select used quantity (1-15, number of packaging items used to make a package) 

Start calibration and follow screen prompts 

5.4 CALIBRATING BANKNOTES AND COINS

 

Refer to a separate document: 

http://www.noteandcoin.com/files/NCS2010_Calibration_procedure.pdf 

6.0 LOOSE BANKNOTES TOLERANCE 

The default settings normally do not require change 

For more information visit  

http://www.noteandcoin.com/Adjusting_banknote_tolerance.html

 

7.0 PRINT FUNCTIONS 

Press PRINT key to display print options 

Print Single  Print running totals for currently selected denomination 

Print Total  Print grand total 

Auto Print  Press ENT

 

 key to toggle automatic print option 

 

(Every time a count is registered, it will be printed automatically with current date & time) 

Print Menu  Press ENT

 

 key to view saved data or PRINT key to print it 

While viewing, use   and   keys

 

to change between coins and banknotes screen 

Press PRINT key to individually print coins or banknotes 

8.0 POWER MANAGEMENT 

Banknote and coin counter can be operated from internal battery or mains charger (included) 

The following battery status indication is provided via front panel LED: 

Red steady 

Battery voltage too low   Recharge immediately 

Red flashing 

Battery low warning 

Recharge when possible 

Green flashing  Battery is charging 

Light off 

Battery charging completed 

TO PREVENT BATTERY DAMAGE, BANKNOTE AND COIN COUNTER 

SHOULD BE CHARGED AT LEAST ONCE EVERY SIX MONTHS

 

Copyright © 2010 Noteandcoin 

Print 

Denomination 

ENT (middle key) 

 

ESC 

Auto 

Denomination 

Power 

Count 

mode 

Count 

mode 

www.noteandcoin.com 

Отзывы: