background image

1.0 GENERAL OPERATION 

Press POWER       key to switch counter on. Press and hold POWER

 

  key to switch counter off. 

Use  

and       keys to select a desired count mode of operation (section 2.0) 

Use  

and        

keys to select a required denomination 

Use ENT

    

  key to abort count when the counter has banknotes or coins or reset current denomination 

when the counter is empty. Press and hold ENT       key to reset / save all running totals 
Use AUTO

 

   key to automatically detect (sections 2.8 & 2.9) or scroll denominations (sections 2.2 & 2.7

Scroll direction:

 

 

 

Lower to higher denomination scroll symbol 

   Higher to lower denomination scroll symbol 

  Lower to higher and back to lower denomination scroll symbol 

Press PRINT            

key to display print options (section 7.0

Press ESC 

key to change loose banknotes tolerance (section 6.0

Up to nine count modes of operation (sections 2.1 to 2.9) are available and can be enabled or disabled from 
appearing on the main screen. Banknote and coin counter should be customised before use to only utilise the 

required count modes. Refer to section 3.4 for details. 

2.0 COUNT MODES 

This section describes available count modes of operation. Select a required count mode using   and   keys  

2.1 LOOSE BANKNOTES AND COINS 

For counting loose banknotes refer to section 2.2 

For counting loose coins refer to section 2.7 

2.2 LOOSE BANKNOTES 

Select denomination using   and   keys 

Place up to 100 banknotes of the same denomination on the note counter. 

Add more banknotes or remove some banknotes if necessary 

Final count will be registered when all banknotes are removed from the note counter 
(AUTO key can be used to enable automatic indexing of denominations after a count is registered) 

2.3 PACKAGED BANKNOTES - FLATS 

(10 banknotes of the same denomination retained with elastic band, paper strap, clip, etc) 

Select denomination using   and   keys 

Place a pack of 10 banknotes on the counter. Add or remove one pack at a time if necessary 

“OVER” or “UNDER” warning will appear if a pack contains more or less than 10 banknotes 

Final count will be registered when all banknotes are removed from the note counter 
(Packaging items such as elastic bands, clips, etc. may have to be calibrated before use (section 

5.3

2.4 PACKAGED BANKNOTES - BUNDLES 

(100 banknotes of the same denomination retained with elastic band, clip, etc.) 

Select denomination using   and   keys 

Place a bundle of banknotes on the counter. Add or remove one bundle at a time if necessary 

Final count will be registered when all bundles are removed from the note counter 
(Packaging items such as elastic bands, clips, etc. may have to be calibrated before use (section 

5.3

2.5 PACKAGED BANKNOTES – SLEEVES (SLEEVED BUNDLES) 

(100 banknotes of the same denomination retained with paper or plastic strap) 

Operation is identical to Bundles above 
(Packaging items such as elastic bands, clips, etc. may have to be calibrated before use (section 

5.3

2.6 PACKAGED BANKNOTES – BUNDLED FLATS 

(10 flats, each retained with one elastic band plus 2 elastic bands retaining the 10 flats)  

Operation is identical to Bundles above 
(Packaging items such as elastic bands, clips, etc. may have to be calibrated before use (section 

5.3

2.7 LOOSE COINS 

Banknote and Coin counter is supplied with a scoop, used only for counting loose coins. 

Select denomination using 

 

and 

 

keys 

Place either an empty scoop or scoop with coins on the coin counter 

Add more coins of the same denomination or remove some coins if necessary 

Final count will be registered when the scoop with coins is removed from the coin counter 
(AUTO key can be used to enable automatic indexing of denominations after a count is registered) 

2.8 PLASTIC BAG COINS 

(Bagged coins of the same denomination) 

Select denomination using   and   keys 

Place a single bag of coins on the coin counter. Add or remove one bag at a time if necessary 

Final count will be registered when all bags are removed from the coin counter 

For automatic denomination recognition of standard bag quantities: 

Press AUTO key (“A“ symbol will be displayed) 

Place a bag of coins (correct denomination will be displayed). Remove the bag to register a count 
(Automatic detection will recognise bags that have up to 2 extra coins or short of 2 coins) 

2.9 PAPER ROLLS COINS 

(Wrapped Coins of the same denomination). Operation is identical to Plastic Bag Coins above 

3.0 SETUP MENU 

Press and hold POWER 

key

 to switch note and coin counter off. Press ESC key to enter setup menu 

3.1 STANDBY TIME 

To save battery power, banknote and coin counter will enter standby after a period of inactivity determined 

by STANDBY setting. Select shortest practical standby time 

Use   and   keys to change standby time 

3.2 CONTRAST 

Use   and   keys to change LCD contrast to personal preference 

3.3 BACKLIGHT TIME 

LCD backlight uses significant amount of battery power. The backlight will be switched off after a period of 
inactivity determined by BACKLIGHT setting. Select shortest practical backlight time 

Use   and   keys to change or disable backlight time 

3.4 COUNT MODES SELECT MENU 

Use   and   keys to highlight a required count mode 

Press ENT key to enable or disable currently highlighted mode 
A   symbol indicates that the mode is enabled and   symbol indicates that the mode is disabled 
(At least 1 mode must be enabled in order to operate banknote and coin counter) 

3.5 SET TIME AND DATE 

Real time clock is used to record running totals for saving and printing counted data. For more information  
visit 

http://www.noteandcoin.com/Printing_and_viewing.html

 

Use   and   keys to select time or date and press ENT key to change 

Use   and   keys to change between HRS-MIN-SEC as well as DD-MM-YY. Press ENT key to set 

4.0 NON-CASH ITEM COUNTER AND WEIGHING SCALES 

Press and hold POWER key to switch counter off. Press   key to alternate between counter and scales mode 

4.1 NON-CASH ITEM COUNTER 

Press AUTO key to calibrate items to be counted. Select sample quantity and start calibration 

Place up to 3Kg of items to be counted on the item counter 
(ENT key can be used to abort count if the counter has items or reset total if the counter is empty) 

4.2 WEIGHING SCALES 

Use   and   keys to change engineering units when the scales are empty 

Place up to 3Kg of items to be weighed on the scales 
(AUTO key can be used to tare the scales if necessary and PRINT key to print the result) 

Отзывы: