8.2. ATEX reed contact 41R57**
ATEX N/O contact 41R57
II 3G Ex ic IIC T4 Gc
II 3 D Ex ic IIIC T125 °C Dc
-20 °C ≤Ta≤80 °C
max. 250 V
AC/DC
/1.5 A/100 W/100 VA
ATEX changeover contact 41R57U
II 3G Ex ic IIC T4 Gc
II 3 D Ex ic IIIC T125 °C Dc
-20 °C ≤Ta≤80 °C
max. 250 V
AC/DC
/1 A/30 W/60 VA
Ex-relevant excerpt of the operating instructions of the reed contact
41R57 **
1. Preambel
This excerpt of the operating instructions only represents the ex-relevant aspects.
It is copied into the original operating manual in the same or analogous form;
Textual changes are permitted, the ex-relevant statements remain.
To ensure the function and for your own safety, please read the enclosed operating
instructions carefully before you begin the installation. If you have any questions,
please contact the KOBOLD Messring GmbH, Hofheim. It applies with the original
operating instructions.
The following standard issues were considered in the evaluation of the product:
a)
IEC 60079-0:2017 Ed. 7 / EN 60079-0:2018 Explosive atmospheres –
Part 0: Equipment - General requirements
b)
IEC 60079-11:2011 Ed. 6 + Corr. 2012 / EN 60079-11:2012 Explosive
atmospheres - Part 11: Equipment protection by intrinsic safety "i"
2. General information on explosion protection
The reed switches work together with various KOBOLD products and serve there
for monitoring. It is available as N/O contact or changeover contact.
The electrical connection is made via a plug - only in intrinsically safe systems.
The reed switch is intended for commercial use and may only be used in
accordance with the specifications in the technical documentation of Kobold and
the information on the nameplate. It is only operated together with certified products
via an intrinsically safe circuit. They comply with the valid standards and
regulations.
The installation regulations (e.g. EN 60079-14) for systems in potentially explosive
atmospheres must be observed.
Further important details can be found in the corresponding EC-type examination
certificate.
Содержание VKG
Страница 1: ...Operating Instruction for Viscosity Compensated Flow Meter and Monitor Model VKG ...
Страница 8: ...VKG Page 8 VKG K09 0322 ...
Страница 24: ...VKG Page 24 VKG K09 0322 17 EU Declaration of Conformance Reed contact 41R57 ATEX not available in GB ...
Страница 25: ...VKG VKG K09 0322 Page 25 18 Statement of conformity reed contact 41R57 ATEX not available in GB ...
Страница 26: ...VKG Page 26 VKG K09 0322 ATEX not available in GB ...
Страница 27: ...VKG VKG K09 0322 Page 27 ATEX not available in GB ...
Страница 28: ...VKG Page 28 VKG K09 0322 ATEX not available in GB ...