![Kobold VKG Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/kobold/vkg/vkg_operating-instructions-manual_1982520010.webp)
VKG
Page 10
VKG K09/0322
Permitted use
• The intrinsically safe reed switch can be used as follows:
• In Zone 2 (Gas-Ex, EPL Gc) in explosion groups IIA, IIB and IIC
• In Zone 22 (Dust-Ex, EPL Dc) in explosion groups IIIA, IIIB and IIIC
• The requirements for simple electrical equipment for use in intrinsically safe
circuits in zones 1/21 are fulfilled.
• The qualification regarding the surface temperature is T4. For all gases, vapors,
mists with an ignition temperature> 135 ° C the equipment is not an ignition
source.
• In the dust Ex area, 125 ° C is the reference temperature for further
consideration regarding the safety distance from the smoldering temperature.
• The ambient temperature range is -20 ° C ≤ Ta ≤ 80 ° C.
2.1. Electrical characteristics for Ex i
Electrical data:
• Rated voltage up to 45 volt AC / DC
• Rated current up to 2 A
• Ui
IC
≤ 30 V AC / DC, Ii
IIC
≤ 250 mA
• Ui
IIB
≤ 45 V AC / DC, Ii
IB
≤ 2 A
• Ui
IIIC
≤ 45 V AC / DC, Ii
IIIC
≤ 250 mA
• L
i
= negligible, Ci = negligible
• Heating on the outer housing <15 K
2.2 Type code
The equipment is identified by the following type code:
Type
Description
Item-No.
Remarks
41R57 A B
Type coding
41R57
Contact device
A
N/O contact (2 wires), Plug with black cap
Change-over contact (3 wires), Plug with grey
cap
B
70 – 75 with marking (not ex-relevant)
202.289
N/O
45 – 50 with marking
202.285
N/O
50 – 55 with marking
202.286
N/O
60 – 65 with marking
202.287
N/O
70 – 75 with marking
202.288
Change-over
60 – 65 change-over contact
202.290
Change-over
2.3 Temperature class
The reed switch is suitable for temperature class T4 / T125 ° C.
Содержание VKG
Страница 1: ...Operating Instruction for Viscosity Compensated Flow Meter and Monitor Model VKG ...
Страница 8: ...VKG Page 8 VKG K09 0322 ...
Страница 24: ...VKG Page 24 VKG K09 0322 17 EU Declaration of Conformance Reed contact 41R57 ATEX not available in GB ...
Страница 25: ...VKG VKG K09 0322 Page 25 18 Statement of conformity reed contact 41R57 ATEX not available in GB ...
Страница 26: ...VKG Page 26 VKG K09 0322 ATEX not available in GB ...
Страница 27: ...VKG VKG K09 0322 Page 27 ATEX not available in GB ...
Страница 28: ...VKG Page 28 VKG K09 0322 ATEX not available in GB ...