7. Electrical connection
VERY IMPORTANT
Be sure that power supply corresponds with the indicated in the equipment’s
label.
GREEN led lighting indicates that equipment is powered
RED led lighting indicates that output relay is activated.
Using SELECTOR 1, you can choose relay operation NO or NC when the
product covers the probe.
Protection fuse of 0.5mA must be put in serial with supply line.
Ground terminal is internally tied to the connection thread.
Be sure that ground line has same potential than ground of thank.
If you are not sure, please do not connect the ground terminal since the
instrument could be damaged.