13. Safety advice 

Please read the following safety advice and the assembly 

chapter 5 

before 

installation and keep it for future reference 
 

Proper use 
 

The 

DAG-A…device

 is designed for the evaluation and display of sensor signals. 

 
  

Danger! Careless use or improper operation can result in         

 

 

Personal injury and / or damage to the equipment. 

 

 

Control of the device 

The panel meters are checked before dispatch and sent out in perfect condition. 
Should there be any visible damage, we recommend close examination of the 
packaging. Please inform the supplier immediately of any damage. 

 

Installation 

The 

DAG-A…device 

must be installed by a suitably 

qualified specialist

  

(e.g. with a qualification in industrial electronics). 

 

Notes on installation 

 

There must be no magnetic or electric fields in the vicinity of the device, e.g. due 
to transformers, mobile phones or electrostatic discharge.

 

 

The 

fuse rating

 of the supply voltage should not exceed a value of 

0.5 A N.B 

fuse

.

 

 

Do  not  install 

inductive  consumers

  (relays,  solenoid  valves  etc.)  near  the 

device  and 

supress

  any  interference  with  the  aid  of  RC  spark  extinguishing 

combinations or free-wheeling diodes.

 

 

Keep input, output and supply lines separate from one another and do not lay 
them  parallel  with  each  other.  Position  “go”  and  “return”  lines  next  to  one 
another.  Where  possible  use  twisted  pair.  So,  you  receive  best  measuring 
results.

 

 

Screen off and twist sensor lines. Do not lay current-carrying lines in the vicinity. 
Connect the 

screening on one side

 on a suitable potential equalizer (normally 

signal ground).

 

 

The  device  is  not  suitable  for  installation  in  areas  where  there  is  a  risk  of 
explosion.

 

 

Any  electrical  connection  deviating  from  the  connection  diagram  can  endanger 
human life and / or can destroy the equipment

 

 

The terminal area of the devices is part of the service. Here electrostatic discharge 
needs to be avoided. Attention! High voltages can cause dangerous body currents.

 

 

Galvanic  insulated  potentials  within  one  complex  need  to  be  placed  on  an 
appropriate  point  (normally  earth  machines  ground).  So,  a  lower  disturbance 
sensibility against impacted energy can be reached and dangerous potentials, that 
can occur on long lines or due to faulty wiring, can be avoided.

 

 

Содержание DAG-A44 Series

Страница 1: ...Operating Instructions for Digital Indicating Unit PT100 2 3 wire 200 C 850 C 328 F 1562 F Model DAG A44 96 x 48 mm...

Страница 2: ...s 2 2 Note 3 3 Instrument Inspection 4 4 Regulation Use 4 5 Assembly 5 6 Electrical connection 6 7 Function and operation description 7 8 Setting up the device 8 8 1 Switching on 8 8 2 Standard parame...

Страница 3: ...uct version you can request it from us free of charge by email info de kobold com in PDF format specifying the relevant invoice number and serial number If you wish the operating instructions can also...

Страница 4: ...damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery The standard delivery includes Description instrument mode...

Страница 5: ...oving the fixing elements insert the device 2 Check the seal to make sure it fits securely 3 Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to...

Страница 6: ...trinsic potential can be cancelled by a bridge from terminal 2 to 4 and thus stabilise the device against external failures Devices with a supply of 230 VAC need to connect terminal 3 to signal ground...

Страница 7: ...tion Level The parameters stored in the menu item can be parameterized here Functions that can be adjusted or changed are always indicated with a flashing of the display Adjustments made at the parame...

Страница 8: ...uence For 1 second during the switch on progress the segment test 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the st...

Страница 9: ...DAG A44 DAG A44 K05 0123 page 9...

Страница 10: ...K05 0123 8 3 Extended parameterization By pressing the buttons during standard parameterization for one second the display switches to the extended parameterization mode Operation is the same as in st...

Страница 11: ...DAG A44 DAG A44 K05 0123 page 11...

Страница 12: ...the Alarm S1 S2 is off below the threshold and on on reaching the Threshold Limit value undercut Low By limit value undercut the alarm S1 S2 is on below the threshold and switched off on reaching the...

Страница 13: ...ing procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are...

Страница 14: ...n Operating instructions data sheet approvals and further information via the QR code on the device or via www kobold com 12 Order Codes Operating instructions data sheet approvals and further informa...

Страница 15: ...s relays solenoid valves etc near the device and supress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes Keep input output and supply lines separate from o...

Страница 16: ...DAG A44 page 16 DAG A44 K05 0123 14 Error elimination...

Страница 17: ...ional disposal regulations and environmental regulations Batteries Batteries containing pollutants are marked with a sign consisting of a crossed out garbage can and the chemical symbol Cd Hg Li or Pb...

Страница 18: ...9 Safety requirements for electrical equipment for measurement control and laboratory use EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 Genera...

Отзывы: