10. Factory settings  

10.1  Default values 

 

 

 
 

10.2  Reset to default values 

To return the unit to a 

defined basic state

, a reset can be carried out to the default 

values. 
 
The following procedure should be used: 
 

  Switch off the power supply 

  Press button 

[P]

 

  Switch on voltage supply and press 

[P]-

button until 

“- - - -“

 

is shown in the 

display. 

 
With  reset,  the  default  values  of  the  program  table  are  loaded  and  used  for 
subsequent operation. This puts the unit back to the state in which it was supplied. 
 

Caution! All application-related data are lost. 

 
 
 
 

 

Parameter 

Menu items 

Default 

or 

to 

to 

to 

to 

to 

to 

to 

to 

Содержание DAG-A44 Series

Страница 1: ...Operating Instructions for Digital Indicating Unit PT100 2 3 wire 200 C 850 C 328 F 1562 F Model DAG A44 96 x 48 mm...

Страница 2: ...s 2 2 Note 3 3 Instrument Inspection 4 4 Regulation Use 4 5 Assembly 5 6 Electrical connection 6 7 Function and operation description 7 8 Setting up the device 8 8 1 Switching on 8 8 2 Standard parame...

Страница 3: ...uct version you can request it from us free of charge by email info de kobold com in PDF format specifying the relevant invoice number and serial number If you wish the operating instructions can also...

Страница 4: ...damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery The standard delivery includes Description instrument mode...

Страница 5: ...oving the fixing elements insert the device 2 Check the seal to make sure it fits securely 3 Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to...

Страница 6: ...trinsic potential can be cancelled by a bridge from terminal 2 to 4 and thus stabilise the device against external failures Devices with a supply of 230 VAC need to connect terminal 3 to signal ground...

Страница 7: ...tion Level The parameters stored in the menu item can be parameterized here Functions that can be adjusted or changed are always indicated with a flashing of the display Adjustments made at the parame...

Страница 8: ...uence For 1 second during the switch on progress the segment test 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the st...

Страница 9: ...DAG A44 DAG A44 K05 0123 page 9...

Страница 10: ...K05 0123 8 3 Extended parameterization By pressing the buttons during standard parameterization for one second the display switches to the extended parameterization mode Operation is the same as in st...

Страница 11: ...DAG A44 DAG A44 K05 0123 page 11...

Страница 12: ...the Alarm S1 S2 is off below the threshold and on on reaching the Threshold Limit value undercut Low By limit value undercut the alarm S1 S2 is on below the threshold and switched off on reaching the...

Страница 13: ...ing procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are...

Страница 14: ...n Operating instructions data sheet approvals and further information via the QR code on the device or via www kobold com 12 Order Codes Operating instructions data sheet approvals and further informa...

Страница 15: ...s relays solenoid valves etc near the device and supress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes Keep input output and supply lines separate from o...

Страница 16: ...DAG A44 page 16 DAG A44 K05 0123 14 Error elimination...

Страница 17: ...ional disposal regulations and environmental regulations Batteries Batteries containing pollutants are marked with a sign consisting of a crossed out garbage can and the chemical symbol Cd Hg Li or Pb...

Страница 18: ...9 Safety requirements for electrical equipment for measurement control and laboratory use EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 Genera...

Отзывы: