background image

3/8 

September

 / 2006

 

 

 

   

I.- OPERATING TEST 

 
The vacuum cleaner can work from 105 to 135 V. 
 
The current must be of  3 to 4 Amps.  
 
There should be no abnormal noise or vibration, the carbon brushes spark should be small and uniform, and the commutator 
must have dark brown strip and uniform. 

 

 

II.-REPLACEMENT PROCEDURES 

 
1.- TO REPLACE MOTOR (7) 

1.1.- Pull release tab outward, at the same time pull cover up. 
1.2.- Remove the four screws (12). 
1.3.- Remove the cover (4). 
1.4.- Disconnect the line cord. ( 7-6E)  
1.5.- Remove the six screws (9) and remove the motor assy (7)  
1.6.- Replace the motor (7) reconnect and reassemble. 
 
NOTE: Do not attempt to the repair motor send for service. 

 

2.- TO REPLACE THE ON-OFF SWITCH (2) 

2.1.- Follow steps 1.1 and 1.3. 
2.2.- Disconnect the two leads  ( 2-2 ) from the switch (2). 
Remove the three screws (6) the screw (5) and remove the cover top (3-1) replace the on-off switch reconnect and 
reassemble. 

 

3.- TO REPLACE THE LINE CORD ( 7-6E) 

3.1.- Follow steps 1.1 and 1.3. 
3.2.- Remove and replace the new line cord and reassemble as initially placed

 

4.- TO REPLACE THE FLOAT (14) 

4.1.- Follow step 1.1 
4.2.- Remove the cage (15). 
4.3.- Remove and replace the float (14) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PV-3000 LR

Страница 1: ...2006 WET DRY VACUUM CLEANER MODELS PV 3000 LR PV 3000 GR DV3 120 V 50 60 Hz 3 4 Amp KOBLENZ ELECTRICA S A DE C V E mail thorne_scsm koblenz electric com September 06 LP VPV 200609 SERVICE MANUAL PARTS...

Страница 2: ...2 8 September 2006 INDEX PAGE I OPERATING TEST 3 II REPLACEMENT PROCEDURES 3 III TROUBLE SHOOTING CHART 4 IV WIRING DIAGRAM 5 V VACUUM CLEANER ASSEMBLY 6 VI VACUUM CLEANER PARTS LIST 7...

Страница 3: ...e line cord 7 6E 1 5 Remove the six screws 9 and remove the motor assy 7 1 6 Replace the motor 7 reconnect and reassemble NOTE Do not attempt to the repair motor send for service 2 TO REPLACE THE ON O...

Страница 4: ...e Switch Line cord open Replace cord Motor Open Replace motor 2 LOW SUCTION CAUSE SOLUTION Tank full Empty tank Hose or wand closed Clean obstruction Motor slow Check carbon brushes Filler is dirty Re...