background image

 

 

Preparation Before Installation 

NOTE:    TO  AVOID  DAMAGE  TO  YOUR  HOOD,  PREVENT  DEBRIS 
FROM ENTERING THE VENT OPENING. 

 

Decide  the  location  of  the  venting  pipe  from  the  hood  to  the 
outside.  Refer to Figure 1. 

 

A  straight,  short  vent  run  will  allow  the  hood  to  perform more 
efficiently. 

 

Try  to  avoid  as  many  transitions,  elbows,  and  long  run  as 
possible.  This may reduce the performance of the hood. 

 

Temporarily  wire  the  hood  to  test  for  proper  operation  before 
installing. 

 

Important:  Peel protective film off the hood, if any. 

 

Use duct tape to seal joints between pipe sections. 

CAUTION

:  If moving the cooking range is necessary to 

install the hood, turn off the power in an electric range at 
the  main  electrical  box.    SHUT  OFF  THE  GAS  BEFORE 
MOVING A GAS RANGE.  And use a protective covering to 
protect cooktop and/or countertop from damage. 

Custom Hood Preparation 

1.  The custom hood frame must be designed based on the shape 

and  the  weight  of  the  hood.    Refer  to  Measurements  and 
Diagrams of hood on Page 11-13.   

2.  A sturdy base (3/4 inch thick plywood recommended) is needed 

to sustain the weight of hood. 

3.  It  is  recommended  to  install  front  &  rear  stud  support  (not 

included).    Refer  to  Figure  2.    For  safety  purposes,  extra 
installation holes on the side of the hood are provided.  Prepare 
the side stud support if needed.   

4.  Determine and mark the centerlines on the base of the wood 

frame where the hood will be installed.  

5.  Determine  the  proper  location  for  the  Power  Supply  Cable.  

Make  a  wiring  access  hole  using  a  drill  bit.      Install  the  wire 
cable and seal the gap around hole. 

6.  Cut out the opening where the hood will be installed. (Refer to 

Figure 3 for appropriate dimensions based on width of hood.) 

Wiring to Power Supply  

 

CAUTION

:  If moving the cooking range is necessary to 

install the hood, turn off the power in an electric range at 
the  main  electrical  box.    SHUT  OFF  THE  GAS  BEFORE 
MOVING A GAS RANGE. RISK OF ELECTRICAL SHOCK.   

  THIS  RANGE  HOOD  MUST  BE  PROPERLY  GROUNDED.  

MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN 
IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND 
LOCAL  ELECTRICAL  CODES.    BEFORE  CONNECTING 
WIRES,  SWITCH  POWER  OFF  AT  SERVICE  PANEL  AND 
LOCK  SERVICE  PANEL  TO  PREVENT

 

POWER  FROM 

BEING SWITCHED ON ACCIDENTALLY. 

7.  Temporarily  wire  the  hood  to  test  for  proper  operation  before 

installing. If the hood does not operate, check the circuit breaker 
or house fuse. If the hood is still not working, disconnect power 
supply and check the continuity of all wire connections.  

8.  If hood is operating normally, connect three wires (black, white 

and green) to house wires and cap with wire connectors. 

9.  Store wires in the wiring box.   

 
Figure 1 
 
 
 
 
 
 
 
                       
 
 
 
 
 
Figure 2 

 

    

Figure 3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 

 

 

 

IN2636SQB-1200-1 (36”) 

IN2642SQB-1200-1 (42”) 

IN2648SQB-1200-1 (48”) 

Содержание IN2642SQB-1200-1

Страница 1: ...KOBE Range Hoods Model No IN2636SQB 1200 1 IN2642SQB 1200 1 IN2648SQB 1200 1 PREMIUM IN26 SERIES INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Страница 2: ...OBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replaceme...

Страница 3: ...E 9 SPECIFICATIONS 10 MEASUREMENTS DIAGRAMS 11 PARTS LIST 14 CIRCUIT DIAGRAM 16 TROUBLE SHOOTING 17 WARRANTY 18 WARRANTY INFORMATION FORM 20 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R...

Страница 4: ...atment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automati...

Страница 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Страница 6: ...x A KOBE Range Hood B Warranty Registration Card C Quick Reference Guide D Baffle Filter x 2 36 x 3 42 48 E Oil Tunnel F Stainless Steel Spacer x 2 For 36 48 G Power Cord H Twist on Wire Cap I Screws...

Страница 7: ...NSERT TABLE 1 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Height of Counter Top to Wood Frame Bottom Minimum 27 to 30 D Height of Wood Frame SAFETY WARNING HOOD MAY HAV...

Страница 8: ...provided Prepare the side stud support if needed 4 Determine and mark the centerlines on the base of the wood frame where the hood will be installed 5 Determine the proper location for the Power Suppl...

Страница 9: ...nce Carefully remove the light support panel 14 Position the hood inside the custom wood frame and secure the hood to the front and rear stud support Refer to Figure 2 by using the front and rear moun...

Страница 10: ...e Delay Shutoff To activate the 3 minute delay shutoff press and hold the power button for about 3 seconds Once the delay shutoff has been activated the LED display will flash and the fan speed will c...

Страница 11: ...lash while ECO Mode is operating on QuietMode To deactivate press and hold the ECO button until the E icon no longer appears in the LED display NOTE Press the power button while ECO Mode is active wil...

Страница 12: ...ft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5...

Страница 13: ...Wireless Remote Control Sold Separately LIGHTS 3 Level Lighting 2 x LED Lights 3W 36 3 x LED Lights 3W 42 48 HOOD DIMENSION W X D X H IN2636SQB 1200 1 34 3 8 x 22 1 2 x 12 IN2642SQB 1200 1 40 3 8 x 22...

Страница 14: ...MENTS DIAGRAMS All are in millimeter All inch measurements are converted from millimeters Inch measurements are estimated MODEL NO IN2636SQB 1200 1 36 IN2642SQB 1200 1 42 IN2648SQB 1200 1 48 Side View...

Страница 15: ...12 Bottom View MODEL NO IN2636SQB 1200 1 36 MODEL NO IN2642SQB 1200 1 42 MODEL NO IN2648SQB 1200 1 48...

Страница 16: ...13 Front View MODEL NO IN2636SQB 1200 1 36 MODEL NO IN2642SQB 1200 1 42 MODEL NO IN2648SQB 1200 1 48...

Страница 17: ...L1 0302 0120 590RE Blower System Left L1 0302 0120 590RE 9 Bottom Casing IN2636SQB 1200 1 B101 2636 09 12 IN2642SQB 1200 1 B101 2642 09 12 IN2648SQB 1200 1 B101 2648 09 12 10 Baffle Filter Support IN2...

Страница 18: ...15 MODEL NO IN2636SQB 1200 1 36 IN2642SQB 1200 1 42 IN2648SQB 1200 1 48...

Страница 19: ...16 CIRCUIT DIAGRAM MODEL NO IN2636SQB 1200 1 36 IN2642SQB 1200 1 42 IN2648SQB 1200 1 48...

Страница 20: ...s are not working Hood is not secured in place Check the installation of hood tighten the mounting bracket LED light fixture s is defective Replace LED light fixture s The light wiring s is loose Chec...

Страница 21: ...es and oil cups are not covered by this warranty WHAT IS COVERED This warranty is valid in the United States and Canada It is non transferable and applies only to the original purchaser and does not e...

Страница 22: ...lies or if you fail to provide all necessary documentation for warranty service you will be responsible for all expenses associated with the requested service including parts labor shipping travelling...

Страница 23: ...odel No 3 Serial No For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE...

Страница 24: ...mand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propr...

Отзывы: