background image

 

 

   

KOBE Brand Range Hood 

 

 CH-178 Model 

 

  

  

 

 

INSTALLATION INSTRUCTIONS 

 

AND OPERATION MANUAL 

 

 

 

 

- READ AND SAVE THESE INSTRUCTIONS - 

 

- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING - 

ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN      

ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES. 

Содержание CH-178

Страница 1: ...odel INSTALLATION INSTRUCTIONS AND OPERATION MANUAL READ AND SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ALL WIRING MUST BE DONE BYA PROFESSIONALAND IN ACCORDANCE WITH NATI...

Страница 2: ...rized agent s receipt or if unit is damaged due to misuse poor installation improper use mistreatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any...

Страница 3: ...rease Fire 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray and then turn off the burner KEEP FLAMMABLE OR COMBUSTIBLE MA TERIAL AW AY FROM FLAMES If the flames do not go out immed...

Страница 4: ...PREPARING THE INSTALLA TION LOCA TION SAFETY WARNING INTERIOR OF HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF YOU HAVE TO OPEN THE HOOD FOR CLEANING OR SERVICING NOTE TO AVOID DAMAG...

Страница 5: ...emporarily wire the hood to test for proper operation before installing Before installing please peel protective film off the hood first if any For Mounting on a Cabinet with a Flush Bottom 1 If you n...

Страница 6: ...the back of the hood Fig 4 Turn over the vent piece so that the flat surface is facing you Cut along the indented outline until there is a 3 X 10 opening Fasten plastic vent piece with the raised surf...

Страница 7: ...er strips For a more secure installation you can also use screws from inside the cabinet down into the wood filler strips Make sure the filler strips do not cover the electrical power line access open...

Страница 8: ...7 Vertical Ducting on second floor house Cabinet Transition Elbow Roof Cap 6 RD 7 RD 3 x 10 Duct Transition 6 RD 7 RD 3 x 10 Duct Roof Cap Elbow Cabinet Ceiling Second floor Wall...

Страница 9: ...nnected Strip solid wire 5 16 and strip stranded wire 3 8 2 Connect the power line ground wire to the grounding green lead supplied with the hood 3 Make the electrical connections by fastening the bla...

Страница 10: ...ight CH 178 Series If your range hood is equipped with the QuietMode feature the LED indicator switch will be located to the right of the light switch When the QuietMode switch is turned on the LED in...

Страница 11: ...n both motors on high speed and spray a mild degreaser into the fans Liquid residue will accumulate in the transparent holders located at the back of the safety screen These slide easily in and out fo...

Страница 12: ...metal support from the bottom of the halogen light The halogen light should drop out of the light cavity 3 Gently unplug the defective halogen light and discard Plug in new halogen light MR16 type 12V...

Страница 13: ...PLEASE WEAR PROTECTIVE GLOVES AS INTERIOR OF HOOD MAY HA VE SHARP EDGES 2 Unscrew the knob that holds the fuse by turning counter clockwise and gently pulling it out Discard defective fuse and replace...

Страница 14: ...Check electrical wires were connected correctly Check for loose wires Check switch Check QuietMode connection QuietMode not working Check power is plugged in Check fuse Check electrical wires were con...

Страница 15: ...14 Circuit Diagram Model CH 178 30 36 42...

Страница 16: ...r Vibration Seal 9 Wire Hole Rubber 30 Motor Position Screw 10 Hanger 31 Impeller 11 Hanger Screw 32 Impeller Plastic Cover 12 Hanger Ring 33 Oil Tunnel Ring 13 Rubber Stand 34 Oil Tunnel 14 Rubber Po...

Страница 17: ...16 Model CH 178 30 36 42...

Страница 18: ...r Plastic Cover 9 Wire Hole Rubber 30 Oil Tunnel 10 Hanger 31 Oil Tunnel Ring 11 Hanger Screw 32 Casing Cover 12 Hanger Ring 33 Button Casing Position Screw 13 Wind Box 34 Oil Container 14 Exhaust Win...

Страница 19: ...18 Model CH 178 48...

Страница 20: ...19 Circuit Diagram Model CH 178 48...

Страница 21: ...ine Triple Turbine 48 only QuietMode 330 cfm 1 Sone 38 decibels Exhaust Patented multiple duct opening 6 7 and 3 x 10 top and rear For 48 has two top ducts of 6 7 and 3 x 10 Light Halogen Light 12V 20...

Страница 22: ...t be provided a If the identification number attached to the range hood has been altered rendered illegible or removed b If notice of the defect has not been given within the period applicable c For f...

Страница 23: ...OT BEACCEPTEDAFTER THEALLOCATED DAYS NOTE This item was thoroughly tested and carefully packed in our factory 3 Products must be returned in good working condition with ALL original parts documentatio...

Страница 24: ...tness for purpose imposed on the sale by the laws of the state of sale are limited to two years from the date of original purchase Some states do not allow limitations on the duration of implied warra...

Отзывы: